Frequency doubling technology perimetry for detection of glaucomatous visual field loss

被引:195
作者
Cello, KE
Nelson-Quigg, JM
Johnson, CA
机构
[1] Legacy Clin Res & Technol Ctr, Devers Eye Inst, Discoveries Sight Res Labs, Portland, OR 97208 USA
[2] Univ Calif Davis, Dept Ophthalmol, Davis, CA 95616 USA
关键词
D O I
10.1016/S0002-9394(99)00414-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS: In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous visual field loss. Previous Humphrey Field Analyzer test results were used to classify glaucomatous visual field loss as early (mean deviation no worse than -6 dB), moderate (mean deviation between -6 and -12 dB) or advanced (mean deviation between -12 and -22 dB). RESULTS: Receiver operating characteristic curves showed 100% sensitivity and specificity (area under the curve, 1.0) for detecting advanced glaucomatous visual field loss, approximately 96% sensitivity and 96% specificity (area under the curve, 0.9751) for detecting moderate glaucomatous visual field loss, and approximately 85% sensitivity and 90% specificity (area under the curve, 0.9261) for early glaucomatous visual field loss. CONCLUSIONS: Frequency doubling technology perimetry demonstrates high sensitivity and specificity for detection of early, moderate, and advanced glaucomatous visual field loss. (C) 2000 by Elsevier Science Inc.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 24 条
[11]  
JOHNSON CA, PERIMETRY UPDATE 199
[12]   NON-LINEAR VISUAL RESPONSES TO FLICKERING SINUSOIDAL GRATINGS [J].
KELLY, DH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1981, 71 (09) :1051-1055
[13]   FREQUENCY DOUBLING IN VISUAL RESPONSES [J].
KELLY, DH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1966, 56 (11) :1628-&
[14]  
Kondo Y, 1998, J GLAUCOMA, V7, P261
[15]  
MADDESS T, 1992, CLIN VISION SCI, V7, P371
[16]  
MADDESS T, 1995, INVEST OPHTH VIS SCI, V36, pS335
[17]   CRITERION-FREE PARAMETER-FREE DISTRIBUTION-INDEPENDENT INDEX OF DIAGNOSTIC-TEST PERFORMANCE [J].
MASSOF, RW ;
EMMEL, TC .
APPLIED OPTICS, 1987, 26 (08) :1395-1408
[18]  
QUIGLEY HA, 1987, INVEST OPHTH VIS SCI, V28, P913
[19]   Identification of glaucoma-related visual field abnormality with the screening protocol of frequency doubling technology [J].
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (06) :819-829
[20]  
QUIGLEY HA, 1988, OPHTHALMOLOGY, V95, P357