Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising

被引:24
作者
Deasy, JO [1 ]
Wickerhauser, MV
Picard, M
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Math, St Louis, MO 63110 USA
[3] Ecole Polytech, Palaiseau, France
关键词
Monte Carlo; wavelet threshold de-noising;
D O I
10.1118/1.1508112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Monte Carlo dose calculation method works by simulating individual energetic photons or electrons as they traverse a digital representation of the patient anatomy. However, Monte Carlo results fluctuate until a large number of particles are simulated. We propose wavelet threshold de-noising as a postprocessing step to accelerate convergence of Monte Carlo dose calculations. A sampled rough function (such as Monte Carlo noise) gives wavelet transform coefficients which are more nearly equal in amplitude than those of a sampled smooth function. Wavelet hard-threshold de-noising sets to zero those wavelet coefficients which fall below a threshold; the image is then reconstructed. We implemented the computationally efficient 9,7-biorthogonal filters in the C language. Transform results were averaged over transform origin selections to reduce artifacts. A method for selecting best threshold values is described. The algorithm requires about 336 floating point arithmetic operations per dose grid point. We applied wavelet threshold de-noising to two two-dimensional dose distributions: a dose distribution generated by 10 MeV electrons incident on a water phantom with a step-heterogeneity, and a slice from a lung heterogeneity phantom. Dose distributions were simulated using the Integrated Tiger Series Monte Carlo code. We studied threshold selection, resulting dose image smoothness, and resulting dose image accuracy as a function of the number of source particles. For both phantoms, with a suitable value of the threshold parameter, voxel-to-voxel noise was suppressed with little introduction of bias. The roughness of wavelet de-noised dose distributions (according to a Laplacian metric) was nearly independent of the number of source electrons, though the accuracy of the de-noised dose image improved with increasing numbers of source electrons. We conclude that wavelet shrinkage de-noising is a promising method for effectively accelerating Monte Carlo dose calculations by factors of 2 or more. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2366 / 2373
页数:8
相关论文
共 13 条
[1]   Factoring wavelet transforms into lifting steps [J].
Daubechies, I ;
Sweldens, W .
JOURNAL OF FOURIER ANALYSIS AND APPLICATIONS, 1998, 4 (03) :247-269
[2]   Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques [J].
Deasy, JO .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07) :1765-1779
[3]  
Donoho D. L., 1993, Applied and Computational Harmonic Analysis, V1, P100, DOI 10.1006/acha.1993.1008
[4]  
*EPAPS, EMPHYA629010210 EPAP
[5]  
HALBLEIB JA, 1994, INTEGRATED TIGER SER
[6]  
*INT ORG STAND, 2000, 109181 ISOIEC
[7]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457
[8]   Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning [J].
Li, JS ;
Pawlicki, T ;
Deng, J ;
Jiang, SB ;
Mok, E ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :2969-2985
[9]   Clinical implementation of a Monte Carlo treatment planning system [J].
Ma, CM ;
Mok, E ;
Kapur, A ;
Pawlicki, T ;
Findley, D ;
Brain, S ;
Forster, K ;
Boyer, AL .
MEDICAL PHYSICS, 1999, 26 (10) :2133-2143
[10]  
NEUENSCHWANDER H, 2000, MC 2000 ADV MONT CAR