Three-Dimensional Analysis of Segmental Wall Shear Stress in the Aorta by Flow-Sensitive Four-Dimensional-MRI

被引:133
作者
Frydrychowicz, Alex [1 ]
Stalder, Aurelien F. [1 ]
Russe, Maximilian F. [1 ]
Bock, Jelena [1 ]
Bauer, Simon [1 ]
Harloff, Andreas [2 ]
Berger, Alexander [1 ]
Langer, Mathias [1 ]
Hennig, Juergen [1 ]
Markl, Michael [1 ]
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol & Med Phys, D-79106 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Neurol & Clin Neurophysiol, D-79106 Freiburg, Germany
关键词
flow-sensitive MRI; aorta; wall shear stress; atherosclerosis; arterial remodeling; COMPUTATIONAL FLUID-DYNAMICS; CORONARY-ARTERY-DISEASE; MAGNETIC-RESONANCE; BLOOD-FLOW; THORACIC AORTA; PHASE-CONTRAST; CAROTID BIFURCATION; IN-VIVO; HEALTHY-VOLUNTEERS; PULSATILE FLOW;
D O I
10.1002/jmri.21790
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the distribution and regional differences of flow and vessel wall parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) in the entire thoracic aorta. Materials and Methods: Thirty-one healthy volunteers (mean age = 23.7 +/- 3.3 years) were examined by flow-sensitive four-dimensional (4D)-MRI at 3T. For eight retrospectively positioned 2D analysis planes distributed along the thoracic aorta, flow parameters and vectorial WSS and OSI were assessed in 12 segments along the vascular circumference. Results: Mean absolute time-averaged WSS ranged between 0.25 +/- 0.04 N/m(2) and 0.33 +/- 0.07 N/m(2) and incorporated a substantial circumferential component (-0.05 +/- 0.04 to 0.07 +/- 0.02 N/m(2)). For each analysis plane, a segment with lowest absolute WSS and highest OSI was identified which differed significantly from mean values within the plane (P < 0.05). The distribution of atherogenic low WSS and high OSI closely resembled typical locations of atherosclerotic lesions at the inner aortic curvature and supraaortic branches. Conclusion: The normal distribution of vectorial WSS and OSI in the entire thoracic aorta derived from flow-sensitive 4D-MRI data provides a reference constituting an important perquisite for the examination of patients with aortic disease. Marked regional differences in absolute WSS and OSI may help explaining why atherosclerotic lesions predominantly develop and progress at specific locations in the aorta.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 50 条
[1]  
Bock J., 2007, OPTIMIZED PREPROCESS
[2]   MAGNETIC-RESONANCE VELOCITY VECTOR MAPPING OF BLOOD-FLOW IN THORACIC AORTIC-ANEURYSMS AND GRAFTS [J].
BOGREN, HG ;
MOHIADDIN, RH ;
YANG, GZ ;
KILNER, PJ ;
FIRMIN, DN .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03) :704-714
[3]   BLOOD-FLOW MEASUREMENTS IN THE AORTA AND MAJOR ARTERIES WITH MR VELOCITY MAPPING [J].
BOGREN, HG ;
BUONOCORE, MH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :119-130
[4]   Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects [J].
Bogren, HG ;
Buonocore, MH ;
Valente, RJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (04) :417-427
[5]   Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: The effects of age and coronary artery disease [J].
Bogren, HG ;
Mohiaddin, RH ;
Kilner, PJ ;
JimenezBorreguero, LJ ;
Yang, GZ ;
Firmin, DN .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :784-793
[6]  
Bogren HG, 1999, J MAGN RESON IMAGING, V10, P861, DOI 10.1002/(SICI)1522-2586(199911)10:5<861::AID-JMRI35>3.3.CO
[7]  
2-5
[8]   Complex flow patterns in the great vessels: a review [J].
Bogren, HG ;
Buonocore, MH .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (02) :105-113
[9]   Aneurysm Growth Occurs at Region of Low Wall Shear Stress Patient-Specific Correlation of Hemodynamics and Growth in a Longitudinal Study [J].
Boussel, Loic ;
Rayz, Vitaliy ;
McCulloch, Charles ;
Martin, Alastair ;
Acevedo-Bolton, Gabriel ;
Lawton, Michael ;
Higashida, Randall ;
Smith, Wade S. ;
Young, William L. ;
Saloner, David .
STROKE, 2008, 39 (11) :2997-3002
[10]   Phase-Contrast Magnetic Resonance Imaging Measurements in Intracranial Aneurysms In Vivo of Flow Patterns, Velocity Fields, and Wall Shear Stress: Comparison with Computational Fluid Dynamics [J].
Boussel, Loic ;
Rayz, Vitaliy ;
Martin, Alastair ;
Acevedo-Bolton, Gabriel ;
Lawton, Michael T. ;
Higashida, Randall ;
Smith, Wade S. ;
Young, William L. ;
Saloner, David .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :409-417