MAGNETIC-RESONANCE VELOCITY VECTOR MAPPING OF BLOOD-FLOW IN THORACIC AORTIC-ANEURYSMS AND GRAFTS

被引:74
作者
BOGREN, HG [1 ]
MOHIADDIN, RH [1 ]
YANG, GZ [1 ]
KILNER, PJ [1 ]
FIRMIN, DN [1 ]
机构
[1] ROYAL BROMPTON HOSP,NATL HEART & LUNG INST,LONDON SW3 6LY,ENGLAND
关键词
D O I
10.1016/S0022-5223(95)70102-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging with multidirectional cine velocity mapping was used to study relationships between aortic blood flow patterns and the geometry of thoracic aortic aneurysms and grafts. Ten patients with 13 thoracic aortic aneurysms, single or multiple, or grafts (4) participated in the study, The causes of disease were atherosclerosis (4), Marfan's syndrome (2), trauma (1), and unknown (1), and there were two dissections, Spin-echo imaging and cine velocity mapping in 10 mm thick slices with vertical and horizontal velocity encoding were done, Maps of the two velocity components were processed into multiple computer-generated streaks whose orientation and length corresponded to velocity vectors in the chosen plane, The dynamic arrow maps were compared with previously reported aortic arrow maps from normal subjects, The forward flow occupied the entire lumen in the normal aorta in systole and small vortices were only present in the sinuses of Valsalva, Atherosclerotic aneurysms in the ascending aorta were located at the anterior right and had oblique, eccentric jet flows that created a large secondary vortex in the aneurysm, Patients with Marfan's syndrome had a central jet and two large vortices, one on each side, All other aneurysms, dissections, and grafts had irregular flows and vortices not seen in normal subjects, Magnetic resonance imaging with multidirectional velocity mapping is a powerful noninvasive tool to assess morphologic features and disturbed blood flow in aortic aneurysms and grafts, Recognizably altered flow patterns were found to be associated with altered vessel geometry, The significance of this requires further investigation.
引用
收藏
页码:704 / 714
页数:11
相关论文
共 29 条
[1]  
AMPARO EG, 1984, AM J ROENTGENOL, V143, P1203, DOI 10.2214/ajr.143.6.1203
[2]   BLOOD-FLOW MEASUREMENTS IN THE AORTA AND MAJOR ARTERIES WITH MR VELOCITY MAPPING [J].
BOGREN, HG ;
BUONOCORE, MH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :119-130
[3]   CAROTID AND VERTEBRAL ARTERY BLOOD-FLOW IN LEFT-HANDED AND RIGHT-HANDED HEALTHY-SUBJECTS MEASURED WITH MR VELOCITY MAPPING [J].
BOGREN, HG ;
BUONOCORE, MH ;
GU, WZ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01) :37-42
[4]   PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
MOHIADDIN, RH ;
FIRMIN, DN ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (05) :990-999
[5]   QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
FIRMIN, DN ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 117 (06) :1214-1222
[6]   EVALUATION OF THE AORTA IN THE MARFAN-SYNDROME BY MAGNETIC-RESONANCE-IMAGING [J].
BOXER, RA ;
LACORTE, MA ;
SINGH, S ;
DAVIS, J ;
GOLDMAN, M ;
STEIN, HL .
AMERICAN HEART JOURNAL, 1986, 111 (05) :1001-1002
[8]   ALGORITHMS FOR IMPROVING CALCULATED STREAMLINES IN 3-D PHASE-CONTRAST ANGIOGRAPHY [J].
BUONOCORE, MH .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :22-30
[9]   IDENTIFICATION AND LOCALIZATION OF ANEURYSMS OF THE ASCENDING AORTA BY CROSS-SECTIONAL ECHOCARDIOGRAPHY [J].
DEMARIA, AN ;
BOMMER, W ;
NEUMANN, A ;
WEINERT, L ;
BOGREN, H ;
MASON, DT .
CIRCULATION, 1979, 59 (04) :755-761
[10]  
DIDISHEIM P, 1992, ADV CARDIOVASCULAR E, P189