ALGORITHMS FOR IMPROVING CALCULATED STREAMLINES IN 3-D PHASE-CONTRAST ANGIOGRAPHY

被引:34
作者
BUONOCORE, MH
机构
[1] Department of Radiology, UC Davis Medical Center, Sacramento, California
关键词
3-D IMAGE PROCESSING; PHASE CONTRAST ANGIOGRAPHY; FLOW STREAMLINES; ATHEROSCLEROSIS;
D O I
10.1002/mrm.1910310104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Streamline display is a unique alternative to cross-sectional slice or projection display, because streamlines more clearly show the patterns of blood flow within the vessel. Flow patterns associated with atherosclerosis, such as streamline separation and recirculation, can be quickly identified with this display. Streamlines can be calculated using velocity data obtained from 3-D phase contrast angiographic pulse sequences. However, these streamlines often pass through the wall of vessel or show intraluminal sources and sinks of blood. The author has developed iterative least squares algorithms to improve the realism of streamlines. The velocity data is modified so that the resulting streamlines do not pass through the vessel wall and there are no intraluminal sources or sinks. He has applied the algorithms to velocity data obtained from a flow phantom and the carotid arteries of normal volunteers. Streamlines derived from the processed velocity fields are more realistic and provide more precise flow quantitation.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 20 条
[2]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[3]   BLOOD-FLOW MEASUREMENT USING VARIABLE VELOCITY ENCODING IN THE RR INTERVAL [J].
BUONOCORE, MH .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :790-795
[4]  
BUONOCORE MH, 1992, 10TH ANN M SMRI
[5]  
CHAHED N, 1991, BIORHEOLOGY, V28, P383
[6]  
Cokelet G., 1987, HDB BIOENGINEERING
[7]   SIGNAL-TO-NOISE IN PHASE-ANGLE RECONSTRUCTION - DYNAMIC-RANGE EXTENSION USING PHASE REFERENCE OFFSETS [J].
CONTURO, TE ;
SMITH, GD .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :420-437
[8]   NONTRIGGERED MAGNETIC-RESONANCE VELOCITY-MEASUREMENT OF THE TIME-AVERAGE OF PULSATILE VELOCITY [J].
HOFMAN, MBM ;
KOUWENHOVEN, M ;
SPRENGER, M ;
VANROSSUM, AC ;
VALK, J ;
WESTERHOF, N .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :648-655
[9]   A 2-FLUID MODEL FOR HEMATOCRIT DISTRIBUTION IN MICROVASCULAR NETWORKS [J].
HOKKANEN, JEI .
MEDICAL PHYSICS, 1989, 16 (03) :319-325
[10]   MAPPING FLOW STREAMLINES BY MULTISTRIPE TAGGING [J].
ICENOGLE, MV ;
CAPRIHAN, A ;
FUKUSHIMA, E .
JOURNAL OF MAGNETIC RESONANCE, 1992, 100 (02) :376-381