A randomized crossover study of an oral appliance vs nasal-continuous positive airway pressure in the treatment of mild-moderate obstructive sleep apnea

被引:291
作者
Ferguson, KA
Ono, T
Lowe, AA
Keenan, SP
Fleetham, JA
机构
[1] UNIV BRITISH COLUMBIA,DIV RESP MED,VANCOUVER,BC V5Z 1M9,CANADA
[2] UNIV BRITISH COLUMBIA,DEPT CLIN DENT SCI,VANCOUVER,BC V5Z 1M9,CANADA
关键词
nasal CPAP; obstructive sleep apnea; oral appliances;
D O I
10.1378/chest.109.5.1269
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To compare efficacy, side effects, patient compliance, and preference between oral appliance (OA) therapy and nasal-continuous positive airway pressure (N-CPAP) therapy. Design: Randomized, prospective, crossover study. Setting: University hospital and tertiary sleep referral center, Patients: Twenty-seven unselected patients with mild-moderate obstructive sleep apnea (OSA). Interventions: There was a 2-week wash-in and a 2-week wash-out period, and 2x4-month treatment periods (OA and N-CPAP). Efficacy, side effects, compliance, and preference were evaluated by a questionnaire and home sleep monitoring. Measurements and results: Two patients dropped out early in the study and treatment results are presented on the remaining 25 patients. The apnea/hypopnea index was lower with N-CPAP (3.5+/-1.6) (mean+/-SD) than with the OA (9.7+/-7.3) (p<0.05). Twelve of the 25 patients who used the OA (48%) were treatment successes (reduction of apnea/hypopnea to <10/h and relief of symptoms), 6 (24%) were compliance failures (unable or unwilling to use the treatment), and 7 (28%) were treatment failures (failure to reduce apnea/hypopnea index to <10/h and/or failure to relieve symptoms), Four people refused to use N-CPAP after using the OA. Thirteen of the 21 patients who used N-CPAP were overall treatment successes (62%), 8 were compliance failures (38%), and there were no treatment failures. Side effects were more common and the patients were less satisfied with N-CPAP (p<0.005). Seven patients were treatment successes with both treatments, six of these patients preferred OA, and one preferred N-CPAP as a long-term treatment. Conclusions: We conclude that OA is an effective treatment in some patients with mild-moderate OSA and is associated with fewer side effects and greater patient satisfaction than N-CPAP.
引用
收藏
页码:1269 / 1275
页数:7
相关论文
共 21 条
  • [1] THE EFFECTS OF A NON-SURGICAL TREATMENT FOR OBSTRUCTIVE SLEEP-APNEA - THE TONGUE-RETAINING DEVICE
    CARTWRIGHT, RD
    SAMELSON, CF
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1982, 248 (06): : 705 - 709
  • [2] CARTWRIGHT RD, 1985, ARCH OTOLARYNGOL, V111, P385
  • [3] EFFECT OF ANTERIOR MANDIBULAR POSITIONING ON OBSTRUCTIVE SLEEP-APNEA
    CLARK, GT
    ARAND, D
    CHUNG, E
    TONG, D
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (03): : 624 - 629
  • [4] EFFICACY OF A HERBST MANDIBULAR ADVANCEMENT DEVICE IN OBSTRUCTIVE SLEEP-APNEA
    EVELOFF, SE
    ROSENBERG, CL
    CARLISLE, CC
    MILLMAN, RP
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (04) : 905 - 909
  • [5] EVERITT B, 1989, STAT METHODS MED INV, P1
  • [6] THE SLEEP HYPOPNEA SYNDROME
    GOULD, GA
    WHYTE, KF
    RHIND, GB
    AIRLIE, MAA
    CATTERALL, JR
    SHAPIRO, CM
    DOUGLAS, NJ
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (04): : 895 - 898
  • [7] JONES B, 1989, DESIGN ANAL CROSS OV, P1
  • [8] OBJECTIVE MEASUREMENT OF PATTERNS OF NASAL CPAP USE BY PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA
    KRIBBS, NB
    PACK, AI
    KLINE, LR
    SMITH, PL
    SCHWARTZ, AR
    SCHUBERT, NM
    REDLINE, S
    HENRY, JN
    GETSY, JE
    DINGES, DF
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : 887 - 895
  • [9] VALIDATION OF A PORTABLE SLEEP-APNEA MONITORING DEVICE
    MAN, GCW
    KANG, BV
    [J]. CHEST, 1995, 108 (02) : 388 - 393
  • [10] LABORATORY VALIDATION-STUDY OF A PORTABLE SYSTEM FOR REMOTE RECORDING OF SLEEP-RELATED RESPIRATORY DISORDERS
    ORR, WC
    EIKEN, T
    PEGRAM, V
    JONES, R
    RUNDELL, OH
    [J]. CHEST, 1994, 105 (01) : 160 - 162