Contralateral subtraction: A novel technique for detection of asymmetric abnormalities on digital chest radiographs

被引:35
作者
Li, Q [1 ]
Katsuragawa, S [1 ]
Ishida, T [1 ]
Yoshida, H [1 ]
Tsukuda, S [1 ]
MacMahon, H [1 ]
Doi, K [1 ]
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
contralateral subtraction; chest radiography; image cross correlation; nonlinear image warping;
D O I
10.1118/1.598856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel contralateral subtraction technique has been developed to assist radiologists in the detection of asymmetric abnormalities on a single chest radiograph. With this method, the lateral inclination is first corrected by rotating and shifting the original chest image so that the midline of the thorax is aligned with the vertical centerline of the original chest image. The rotated image is then flipped laterally to produce a reversed "mirror" image. Finally, the mirror image is warped and subtracted from the original image for derivation of the contralateral subtraction image. The three key techniques which are employed in this study are applied successively to the initial contralateral subtraction technique for acquisition of improved subtraction images. One hundred PA chest radiographs, including 50 normals and 50 abnormals, were used as the database for this study. The percentage of chest images, which were rated as being adequate, good, or excellent quality of subtraction images by employing a subjective evaluation method, was improved from 73% to 91% by use of the three key techniques. The contralateral subtraction technique can be used for detection of any asymmetric abnormalities, such as lung nodules, pneumothorax, pneumonia, and emphysema, on a single chest radiograph, and therefore has potential utility in a high proportion of abnormal cases. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 8 条
[1]   Digital chest radiography: Effect of temporal subtraction images on detection accuracy [J].
Difazio, MC ;
MacMahon, H ;
Xu, XW ;
Tsai, P ;
Shiraishi, J ;
Armato, SG ;
Doi, K .
RADIOLOGY, 1997, 202 (02) :447-452
[2]   Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change [J].
Ishida, T ;
Katsuragawa, S ;
Nakamura, K ;
MacMahon, H ;
Doi, K .
MEDICAL PHYSICS, 1999, 26 (07) :1320-1329
[3]   Application of temporal subtraction for detection of interval changes on chest radiographs: Improvement of subtraction images using automated initial image matching [J].
Ishida, T ;
Ashizawa, K ;
Engelmann, R ;
Katsuragawa, S ;
MacMahon, H ;
Doi, K .
JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) :77-86
[4]   DIGITAL IMAGE SUBTRACTION OF TEMPORALLY SEQUENTIAL CHEST IMAGES FOR DETECTION OF INTERVAL CHANGE [J].
KANO, A ;
DOI, K ;
MACMAHON, H ;
HASSELL, DD ;
GIGER, ML .
MEDICAL PHYSICS, 1994, 21 (03) :453-461
[5]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY - AUTOMATED-ANALYSIS OF SIZES OF HEART AND LUNG IN CHEST IMAGES [J].
NAKAMORI, N ;
DOI, K ;
SABETI, V ;
MACMAHON, H .
MEDICAL PHYSICS, 1990, 17 (03) :342-350
[6]  
SHIRAISHI J, 1997, RADIOLOGY S, V205, P394
[7]   IMAGE FEATURE ANALYSIS FOR COMPUTER-AIDED DIAGNOSIS - ACCURATE DETERMINATION OF RIBCAGE BOUNDARY IN CHEST RADIOGRAPHS [J].
XU, XW ;
DOI, K .
MEDICAL PHYSICS, 1995, 22 (05) :617-626
[8]   Development of an improved CAD scheme for automated detection of lung nodules in digital chest images [J].
Xu, XW ;
Doi, K ;
Kobayashi, T ;
MacMahon, H ;
Giger, ML .
MEDICAL PHYSICS, 1997, 24 (09) :1395-1403