Diagnosis of vascular catheter-related bloodstream infection: A meta-analysis

被引:122
作者
SiegmanIgra, Y
Anglim, AM
Shapiro, DE
Adal, KA
Strain, BA
Farr, BM
机构
[1] UNIV VIRGINIA, HLTH SCI CTR, CHARLOTTESVILLE, VA 22908 USA
[2] TEL AVIV UNIV, SACKLER FAC MED, TEL AVIV SOURASKY MED CTR, INFECT DIS UNIT, IL-69978 TEL AVIV, ISRAEL
[3] HARVARD UNIV, SCH PUBL HLTH, DEPT BIOSTAT, BOSTON, MA 02115 USA
关键词
D O I
10.1128/JCM.35.4.928-936.1997
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Catheter-related bloodstream infections increased in incidence during the past decade, causing significant morbidity, mortality, and excess hospital costs, Absence of inflammation at the catheter site in most cases makes clinical diagnosis uncertain, The relative accuracy and cost-effectiveness of different microbiologic tests for confirming that bloodstream infection is catheter related have remained unclear, A meta-analysis of published studies was conducted regarding the accuracy of diagnostic test methods using pooled sensitivity and specificity and summary receiver operating characteristic (ROC) curve analysis, The cost for each test was estimated by methods published by the College of American Pathologists. Costs of catheter replacement and antibiotic therapy for false positive results were included in the cost per accurate test result, Twenty-two studies evaluating six test methods met inclusion criteria for the meta-analysis. Accuracy increased in ROC analysis for catheter segment cultures with increasing quantitation (P = 0.03) (i.e., quantitative > semiquantitative > qualitative) largely due to an increase in specificity. The highest Youden index (mean = 0.85) was observed with quantitative catheter segment culture, the only method,vith pooled sensitivity and specificity above 90%. For blood culture methods, there was no statistically significant trend toward increased accuracy. The unpaired quantitative catheter blood culture offered the lowest cost per accurate test result but was only 78% sensitive, In conclusion, quantitative culture was the most accurate method for catheter segment culture, and unpaired quantitative catheter blood culture was the single most cost-effective test, especially for long-term catheters.
引用
收藏
页码:928 / 936
页数:9
相关论文
共 99 条
  • [41] A COMPARATIVE-STUDY OF INTRAVENOUS CANNULAE - VENFLON WITH VALVED SIDEPORT AND INTRAFLUX WITH MEMBRANOUS SIDEPORT
    JAKOBSEN, CJB
    GRABE, N
    [J]. JOURNAL OF HOSPITAL INFECTION, 1983, 4 (04) : 399 - 402
  • [42] VASCULAR CATHETER-RELATED SEPSIS - DIAGNOSIS AND PREVENTION
    JOHNSON, A
    OPPENHEIM, BA
    [J]. JOURNAL OF HOSPITAL INFECTION, 1992, 20 (02) : 67 - 78
  • [43] SEMIQUANTITATIVE CULTURES OF INTRAVASCULAR CATHETERS FROM CANCER-PATIENTS
    JONES, PG
    HOPFER, RL
    ELTING, L
    JACKSON, JA
    FAINSTEIN, V
    BODEY, GP
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1986, 4 (04) : 299 - 306
  • [44] KARDAUN JWPF, 1990, METHOD INFORM MED, V29, P12
  • [45] KHARDORI N, 1993, 33 INT C ANT AG CHEM
  • [46] EVALUATION OF 3 METHODS FOR CULTURING LONG INTRAVASCULAR CATHETERS
    KRISTINSSON, KG
    BURNETT, IA
    SPENCER, RC
    [J]. JOURNAL OF HOSPITAL INFECTION, 1989, 14 (03) : 183 - 191
  • [47] LINARES J, 1985, J CLIN MICROBIOL, V21, P357
  • [48] ESTIMATING DIAGNOSTIC-ACCURACY FROM MULTIPLE CONFLICTING REPORTS - A NEW METAANALYTIC METHOD
    LITTENBERG, B
    MOSES, LE
    [J]. MEDICAL DECISION MAKING, 1993, 13 (04) : 313 - 321
  • [49] RISKS FROM CANNULAE USED TO MAINTAIN INTRAVENOUS ACCESS
    MACFARLANE, JT
    WARD, MJ
    BANKS, DC
    PILKINGTON, R
    FINCH, RG
    [J]. BRITISH MEDICAL JOURNAL, 1980, 281 (6252) : 1395 - 1396
  • [50] PROSPECTIVE RANDOMIZED TRIAL OF POVIDONE-IODINE, ALCOHOL, AND CHLORHEXIDINE FOR PREVENTION OF INFECTION ASSOCIATED WITH CENTRAL VENOUS AND ARTERIAL CATHETERS
    MAKI, DG
    RINGER, M
    ALVARADO, CJ
    [J]. LANCET, 1991, 338 (8763) : 339 - 343