Measurement of dose within tissues and tissue interfaces having sharp density discontinuities and heterogeneities (such as in the lung, esophagus, and rectum) is essential for treatment plan verification and accurate prediction of the prescribed dose. This study examines the feasibility and utility of simplifying standard film dosimetry to measure dose distributions deposited by megavoltage beams in tissue substitutes (such as cork for lung) and anthropomorphic phantoms which closely resemble human tissues having large density heterogeneities and having sharp tissue interfaces. In addition, film dosimetry determined the dose distribution involving superposition of multiple radiation fields and helped evaluate the accuracy of a commercial treatment planning program which incorporates tissue heterogeneity effects through the ''effective path length'' algorithm. This study shows that these treatment planning programs and simple calculations overestimate the dose delivered within the lower density material in heterogeneous regions. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:455 / 460
页数:6
相关论文
共 15 条
[1]  
BURCH SE, 1994, MED PHYS, V21, P939
[2]   INVESTIGATION OF THE IMAGING PROPERTIES OF AN X-RAY-FILM SCANNER [J].
DOLER, W ;
RASSOW, S ;
JAGER, A ;
VOSSHENRICH, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (05) :917-922
[3]   A SIMPLE TECHNIQUE FOR FILM DOSIMETRY [J].
EVANS, MDC ;
SCHREINER, LJ .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (04) :265-267
[4]  
GRAY AS, 1995, MED PHYS, V22, P952
[5]  
Hale J I, 1994, Med Dosim, V19, P43
[6]   4 MEV X-RAY FILM DOSIMETRY [J].
JACOBSON, A .
RADIOLOGY, 1972, 103 (03) :703-&
[7]   IS CORRECTION FOR LUNG DENSITY IN RADIOTHERAPY TREATMENT PLANNING NECESSARY [J].
MCKENNA, WG ;
YEAKEL, K ;
KLINK, A ;
FRAASS, BA ;
VANDEGEIJN, J ;
GLATSTEIN, E ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (02) :273-278
[8]  
RICE RK, 1986, MED PHYS, V13, P779
[9]   DENSITY PATTERNS IN THE NORMAL LUNG AS DETERMINED BY COMPUTED-TOMOGRAPHY [J].
ROSENBLUM, LJ ;
MAUCERI, RA ;
WELLENSTEIN, DE ;
THOMAS, FD ;
BASSANO, DA ;
RAASCH, BN ;
CHAMBERLAIN, CC ;
HEITZMAN, ER .
RADIOLOGY, 1980, 137 (02) :409-416
[10]   TISSUE MAXIMUM RATIOS (AND OTHER PARAMETERS) OF SMALL CIRCULAR 4, 6, 10, 15 AND 24 MV X-RAY-BEAMS FOR RADIOSURGERY [J].
SERAGO, CF ;
HOUDEK, PV ;
HARTMANN, GH ;
SAINI, DS ;
SERAGO, ME ;
KAYDEE, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1943-1956