Catalytic effect on silver electrodeposition of gold deposited on carbon electrodes

被引:8
作者
de la Escosura-Muñiz, A [1 ]
González-García, MB [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
electrocatalytic deposition of silver; ionic gold; aurothiomalate; carbon paste electrode; glassy carbon electrode; anodic stripping voltammetry;
D O I
10.1002/elan.200302973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new methodology, based on silver electrocatalytic deposition and designed to quantify gold deposited onto carbon paste electrode (CPE) and glassy carbon electrode (GCE), has been developed in this work. Silver (prepared in 1.0 M NH3) electrodeposition at -0.13 V occurs only when gold is previously deposited at an adequate potential on the electrode surface for a fixed period of time. When a CPE is used as working electrode, an adequate oxidation of gold is necessary. This oxidation is carried out in both 0.1 M NaOH and 0.1 M H2SO4 at oxidation potentials. When a GCE is used as working electrode, the oxidation steps are not necessary. Moreover, a cleaning step in KCN, which removes gold from electrode surface, is included. To obtain reproducibility in the analytical signal, the surface of the electrodes must be suitably pretreated; this electrodic pretreatment depends on the kind of electrode used as working electrode. Low detection limits (5.0 x 10(-10) M) for short gold deposition times (10 min for CPE and 5 min for GCE) were achieved with this novel methodology. Finally, sodium aurothiomalate can be quantified using silver electrocatalytic deposition and GCE as working electrode. Good linear relationship between silver anodic stripping peak and aurothiomalate concentration was found from 5.0 x 10(-10) M to 1.0 x 10(-8) M.
引用
收藏
页码:1561 / 1568
页数:8
相关论文
共 23 条
[11]   VOLTAMMETRIC BEHAVIOR OF GOLD AT A DITHIZONE-MODIFIED CARBON-PASTE ELECTRODE [J].
KALCHER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 325 (02) :181-185
[12]   DETERMINATION OF GOLD IN SEPARATE PROTEIN-FRACTIONS OF BLOOD-SERUM BY CARBON FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
KAMEL, H ;
BROWN, DH ;
OTTAWAY, JM ;
SMITH, WE .
ANALYST, 1977, 102 (1218) :645-657
[13]  
Kula P, 2001, ELECTROANAL, V13, P795, DOI 10.1002/1521-4109(200105)13:8/9<795::AID-ELAN795>3.0.CO
[14]  
2-S
[15]   Adsorptive cathodic stripping voltammetric determination of gold(III) in the presence of yeast mannan [J].
Lack, B ;
Duncan, J ;
Nyokong, T .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :393-399
[16]   THE DETERMINATION OF GOLD BY ANODIC-STRIPPING VOLTAMMETRY [J].
LINTERN, M ;
MANN, A ;
LONGMAN, D .
ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) :193-203
[17]  
MARMANTOV G, 1965, J ELECTROANAL CHEM, V9, P305
[18]   Determination of gold using clay modified carbon paste electrode [J].
Navrátilová, Z ;
Kula, P .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (04) :369-372
[19]  
NGHI TV, 1975, J ELECTROANAL CHEM, V64, P163, DOI 10.1016/0368-1874(75)87015-8
[20]   EFFECT OF PROTEIN-CONCENTRATION ON THE BINDING OF GOLD(I) TO HUMAN-SERUM ALBUMIN [J].
PEDERSEN, SM .
BIOCHEMICAL PHARMACOLOGY, 1987, 36 (16) :2661-2666