Ultrastructural analysis of metallic debris and tissue reaction around spinal implants in patients with late operative site pain

被引:18
作者
Senaran, H
Atilla, P
Kaymaz, F
Acaroglu, E [1 ]
Surat, A
机构
[1] Hacettepe Univ, Dept Orthoped & Traumatol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Dept Histol, TR-06100 Ankara, Turkey
关键词
spinal implant; debris; late operative site pain;
D O I
10.1097/01.BRS.0000133646.40087.8B
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Cross-sectional ultrastructural analysis of metallic debris as well as the tissue reaction surrounding spinal implants in patients with late operative site pain. Objective. To clarify the cause of late operative site pain by the ultrastructural analysis of the byproducts of metallic corrosion as well as the surrounding soft tissues. Summary of the Background Data. Late operative site pain has been identified as the most frequent cause of implant removal. Allergic reaction to metal as well as low-grade infection has been suggested as probable mechanisms. Methods. Fourteen spinal implants were removed because of late operative site pain. Tissues obtained from different zones surrounding these implants were analyzed by light microscopy, transmission electron microscopy, and scanning electron microscopy along with electron dispersion radiograph analysis. Results. No signs of infection were present. Either one of the 2 types of connective tissue ( dense or loose) were found to surround the implants. Macrophage counts were most abundant in zone II ( around pedicular screws) when compared to other zones ( zone I: around the rods; zone III: around the transverse rod connectors). In contrast, particulate debris was more abundant and larger in size in specimens from zone III. Two types of metallic debris were identified. The rusty appearing particles contained mostly iron ( Fe), whereas the black appearing particles were rich in chromium (Cr). Conclusion. This study produced useful information regarding the production and distribution of particulate metallic debris around stainless steel spinal implants.
引用
收藏
页码:1618 / 1622
页数:5
相关论文
共 15 条
[11]   A HISTOLOGIC-STUDY OF SOFT-TISSUE REACTIONS TO SPINAL IMPLANTS [J].
MODY, DR ;
ESSES, SI ;
HEGGENESS, MH .
SPINE, 1994, 19 (10) :1153-1156
[12]   PERIPROSTHETIC BONE LOSS IN TOTAL HIP-ARTHROPLASTY - POLYETHYLENE WEAR DEBRIS AND THE CONCEPT OF THE EFFECTIVE JOINT SPACE [J].
SCHMALZRIED, TP ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :849-863
[13]  
Tharani R, 2001, J Bone Joint Surg Am, V83, P774
[14]   MIGRATION OF CORROSION PRODUCTS FROM MODULAR HIP PROSTHESES - PARTICLE MICROANALYSIS AND HISTOPATHOLOGICAL FINDINGS [J].
URBAN, RM ;
JACOBS, JJ ;
GILBERT, JL ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (09) :1345-1359
[15]   Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement [J].
Urban, RM ;
Jacobs, JJ ;
Tomlinson, MJ ;
Gavrilovic, J ;
Black, J ;
Peoc'h, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :457-477