Quantitative analysis of three-dimensional fluid flow in rotating bioreactors for tissue engineering

被引:36
作者
Botchwey, EA
Pollack, SR
Levine, EM
Johnston, ED
Laurencin, CT
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Orthopaed Surg, Charlottesville, VA USA
[3] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[4] Wistar Inst Anat & Biol, Philadelphia, PA 19104 USA
[5] Univ Virginia, Dept Chem Engn, Charlottesville, VA USA
关键词
bioreactor; bone; fluid flow; scaffold; tissue engineering;
D O I
10.1002/jbm.a.10163
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tissue engineering has emerged as a viable alternative to the problem of organ and tissue shortage. Our laboratory has developed matrices for bone tissue engineering based on sintered spherical particles and, using bioreactor technology, has demonstrated the ability to produce highly mineralized matrices in vitro. In this study, porous microcapsule scaffolds were developed for bone tissue engineering in the high aspect ratio vessel rotating bioreactor. The motion of individual microcapsules as well as scaffolds in the bioreactor were studied by numerical simulation and in situ imaging analysis. Results show that spherical microcapsules with density less than the surrounding fluid exhibited two motions: (1) a periodic circular orbit with tangential speed equal to the free fall speed of the particle, and (2) an inward radial migration of the circular orbit toward the center of the bioreactor vessel. Lighter-than-water scaffolds were fabricated by sintering poly(lactic-co-glycolic acid) hollow microcarriers with diameter from 500 to 860 mum into a fixed three-dimensional geometry with approximately 30% pore volume and 180 to 190 mum median pore size. Scaffolds were fabricated with aggregate densities ranging from 0.65 g/mL and 0.99 g/mL by appropriate combinations of hollow and solid microcarriers within the scaffold. Scaffold velocity in the bioreactor for the above range of densities was accurately predicted by numerical simulation and ranged from 100 mm/s to 3 mm/s. Maximum shear stress estimation due to media flow over the exterior of the scaffold ranged from 0.3 N/m(2) to 0.006 N/m(2). Internal perfusion velocity through scaffolds also was calculated and ranged from 13 mm/s to 0.2 mm/s. Estimates of maximum interior shear stress ranged from 0.03 to 0.0007 N/m(2). These analytical methods provide an excellent vehicle for the study of bone tissue synthesis in three-dimensional culture with fluid flow. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:205 / 215
页数:11
相关论文
共 34 条
[1]   Serum modulates the intracellular calcium response of primary cultured bone cells to shear flow [J].
Allen, FD ;
Hung, CT ;
Pollack, SR ;
Brighton, CT .
JOURNAL OF BIOMECHANICS, 2000, 33 (12) :1585-1591
[2]   PREPARATION OF BIODEGRADABLE MICROSPHERES AND MICROCAPSULES .2. POLYACTIDES AND RELATED POLYESTERS [J].
ARSHADY, R .
JOURNAL OF CONTROLLED RELEASE, 1991, 17 (01) :1-21
[3]  
ATTAWIA MA, 1994, ABSTR PAP AM CHEM S, V208, P278
[4]   Tissue engineered microsphere-based matrices for bone repair: design and evaluation [J].
Borden, M ;
Attawia, M ;
Khan, Y ;
Laurencin, CT .
BIOMATERIALS, 2002, 23 (02) :551-559
[5]  
BORDEN MD, 1997, MAT RES SOC P, P352
[6]  
Botchwey EA, 2001, J BIOMED MATER RES, V55, P242
[7]  
BURWELL RG, 1994, BONE GRAFTS, DERIVATIVES AND SUBSTITUTES, P3
[8]   PREPARATION OF POROUS AND NONPOROUS BIODEGRADABLE POLYMERIC HOLLOW MICROSPHERES [J].
CROTTS, G ;
PARK, TG .
JOURNAL OF CONTROLLED RELEASE, 1995, 35 (2-3) :91-105
[9]  
GADZAG AR, 1995, J AM ACAD ORTHOP SUR, V3, P1
[10]  
Gao H, 1997, MICROGRAVITY SCI TEC, V10, P154