Potential of fermentation profiling via rapid measurement of amino acid metabolism by liquid chromatography-tandem mass spectrometry

被引:35
作者
Dalluge, JJ
Smith, S
Sanchez-Riera, F
McGuire, C
Hobson, R
机构
[1] Cargill Inc, Ctr Sci Res, Minneapolis, MN 55440 USA
[2] Cargill Inc, Dev Ctr Biotechnol, Minneapolis, MN 55440 USA
关键词
metabolomics; process monitoring; amino acids;
D O I
10.1016/j.chroma.2004.02.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monitoring amino acid metabolism during fermentation has significant potential from the standpoint of strain selection, optimizing growth and production in host strains, and profiling microbial metabolism and growth state. A method has been developed based on rapid quantification of underivatized amino acids using liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) to monitor the metabolism of 20 amino acids during microbial fermentation. The use of a teicoplanin-based chiral stationary phase coupled with electrospray tandem mass spectrometry allows complete amino acid analyses in less than 4 min. Quantification is accomplished using five isotopically labeled amino acids as internal standards. Because comprehensive chromatographic separation and derivatization are not required, analysis time is significantly less than traditional reversed- or normal-phase LC-based amino acid assays. Intra-sample precisions for amino acid measurements in fermentation supernatants using this method average 4.9% (R.S.D.). Inter-day (inter-fermentation) precisions for individual amino acid measurements range from 4.2 to 129% (R.S.D.). Calibration curves are linear over the range 0-300 mug/ml, and detection limits are estimated at 50-450 ng/ml. Data visualization techniques for constructing semi-quantitative fermentation profiles of nitrogen source utilization have also been developed and implemented, and demonstrate that amino acid profiles generally correlate with observed growth profiles. Further, cellular growth events, such as lag-time and cell lysis can be detected using this methodology. Correlation coefficients for the time profiles of each amino acid measured illustrate that while several amino acids are differentially metabolized in similar fermentations, a select group of amino acids display strong correlations in these samples, indicating a sub-population of analytes that may be most useful for fermentation profiling. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 7
页数:5
相关论文
共 10 条
[1]   Data and knowledge based experimental design for fermentation process optimization [J].
Berkholz, R ;
Röhlig, D ;
Guthke, R .
ENZYME AND MICROBIAL TECHNOLOGY, 2000, 27 (10) :784-788
[2]  
BOX GEP, 1978, STAT EXPT INTRO DESI, P61
[3]   The commercial production of chemicals using pathway engineering [J].
Chotani, G ;
Dodge, T ;
Hsu, A ;
Kumar, M ;
LaDuca, R ;
Trimbur, D ;
Weyler, W ;
Sanford, K .
BIOCHIMICA ET BIOPHYSICA ACTA-PROTEIN STRUCTURE AND MOLECULAR ENZYMOLOGY, 2000, 1543 (02) :434-455
[4]   An integrated approach to optimization of Escherichia coli fermentations using historical data [J].
Coleman, MC ;
Buck, KKS ;
Block, DE .
BIOTECHNOLOGY AND BIOENGINEERING, 2003, 84 (03) :274-285
[5]   State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples [J].
Fekkes, D .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (01) :3-22
[6]  
Godel H., 1992, LC GC INT, V5, P44
[7]   Optimization of media by evolutionary algorithms for production of polyols [J].
Patil, SV ;
Jayaraman, VK ;
Kulkarni, BD .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2002, 102 (1-6) :119-128
[8]   A comparative study of commercial liquid chromatographic detectors for the analysis of underivatized amino acids [J].
Petritis, K ;
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) :9-21
[9]   Parameter optimization for the analysis of underivatized protein amino acids by liquid chromatography and ionspray tandem mass spectrometry [J].
Petritis, K ;
Chaimbault, P ;
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :253-263
[10]   Validated quantitation of underivatized amino acids in human blood samples by volatile ion-pair reversed-phase liquid chromatography coupled to isotope dilution tandem mass spectrometry [J].
Qu, J ;
Wang, YM ;
Luo, G ;
Wu, ZP ;
Yang, CD .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2034-2040