Compensation of Ca and Na interference effects in axially and radially viewed inductively coupled plasmas

被引:35
作者
Brenner, IB
Le Marchand, A
Daraed, C
Chauvet, L
机构
[1] Ben Gurion Univ Negev, Environm Analyt Lab, IL-84105 Beer Sheva, Israel
[2] Jobin Yvon Horiba, F-91160 Longjumeau, France
关键词
D O I
10.1006/mchj.1999.1800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The linear relationship between Ca and Na interferences and energy potentials for a wide range of atomic and ionic lines is used to compensate for variable intensity suppression in robust axially and radially viewed inductively coupled plasmas (ICPs). In the axial configuration, intensity attenuation varied from 0 to 40% in the presence of 0.5% Ca and Na. In the radially viewed ICP, interferences were smaller, varying from 5 to 15% for 0.5% Na and from 10 to 30% for 0.5% Ca. Signal attenuation was broadly a linear function of the energies of the spectral lines. These linear functions were estimated by using spectral lines covering the energy range from Sb I 206.833 (5.98 eV), Y II 371.209 and Sc II 361.384 (9.9 eV), Sc II 255.237 (11.42 eV), and Be II 313.042 (13.28 eV) nm. These functions were then used as variable internal standards to compensate for Ca, Na, and mixed Ca-Na matrix effects. Whereas analyte recoveries without compensation varied from about 40 to 90%, they varied mostly from 100 +/- 5% when these functions were used. In the presence of Ca and Na, the Mg II 280.270/Mg I 285.213 nm intensity ratio decreased from about 12 for an aqueous solution to 9 at 1.5 kW. Such values confirm that the radially and axially viewed ICPs were robust, (C) 1999 Academic Press.
引用
收藏
页码:344 / 355
页数:12
相关论文
共 29 条
[1]   Comparison of axially and radially viewed inductively coupled plasmas for multi-element analysis: Effect of sodium and calcium [J].
Brenner, IB ;
Zander, A ;
Cole, M ;
Wiseman, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :897-906
[2]   Ca and Na interference effects in an axially viewed ICP using low and high aerosol loadings [J].
Brenner, IB ;
Zischka, M ;
Maichin, B ;
Knapp, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) :1257-1264
[3]  
BRENNER IB, 1984, ANAL CHIM ACTA, V166, P51
[4]   A NEW APPROACH TO THE DETERMINATION OF THE MAJOR AND MINOR CONSTITUENTS IN SILICATE AND PHOSPHATE ROCKS [J].
BRENNER, IB ;
WATSON, AE ;
RUSSELL, GM ;
GONCALVES, M .
CHEMICAL GEOLOGY, 1980, 28 (3-4) :321-330
[5]  
BRENNER IB, 1987, AM LAB OCT, P17
[6]   Empirical procedure for the reduction of mixed-matrix effects in inductively coupled plasma atomic emission spectrometry using an internal standard and proportional correction [J].
deBoer, JLM ;
Velterop, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (06) :362-370
[8]   Effect of sodium during the aerosol transport and filtering in inductively coupled plasma atomic emission spectrometry [J].
Dubuisson, C ;
Poussel, E ;
Todoli, JL ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (04) :593-600
[9]   Comparison of axially and radially viewed inductively coupled plasma atomic emission spectrometry in terms of signal-to-background ratio and matrix effects - Plenary lecture [J].
Dubuisson, C ;
Poussel, E ;
Mermet, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :281-286
[10]  
DUBUISSON C, IN PRESS J ANAL AT S