Effects of left ventricular assist device support and outflow graft location upon aortic blood flow

被引:27
作者
Litwak, KN
Koenig, SC
Tsukui, H
Kihara, S
Wu, ZJ
Pantalos, GM
机构
[1] Univ Louisville, Louisville, KY 40202 USA
[2] Univ Louisville, Dept Surg, Heart & Lung Inst, Jewish Hosp, Louisville, KY 40202 USA
[3] Univ Pittsburgh, Dept Surg, Pittsburgh, PA USA
[4] Univ Maryland, Dept Surg, Baltimore, MD 21201 USA
关键词
D O I
10.1097/01.MAT.0000136505.27884.F8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although continuous flow (CFVAD) and pulsatile (PVAD) ventricular assist devices (VADs) are being clinically used, their effects upon aortic blood flow as a measure of overall blood distribution remain unclear. The objective of this study was to compare the effects of CFVAD and PVAD support for ascending (AscA) and descending (DA) aorta outflow cannulation upon mean aortic blood flow and waveform morphology. Six experiments were conducted in a normal, acute calf model, in which an inflow cannula was implanted in the left ventricle apex and outflow cannulae were anastomosed to both the AscA and DA. Flow probes were placed around the pulmonary artery, pump outflow, brachiocephalic trunk, and aorta proximal and distal to the DA outflow. For each acute experiment, calves received randomly selected levels of VAD support (0-100% of cardiac output) and pump failure (VAD off and outflow cannula unclamped) for each of four randomly selected test conditions: (1) PVAD and AscA, (2) PVAD and DA, (3) CFVAD and AscA, and (4) CFVAD and DA. Regardless of pump type or support level, proximal and distal aorta mean flows were lower (p < 0.05) for DA compared with the AscA. No differences in mean aortic flows between pump types at either outflow graft location were discerned. Differences in morphologic features of blood flow waveforms between PVAD and CFVAD were observed. During simulated pump failure, retrograde aortic blood flow in both the aortic arch and DA was observed. Partial ventricular suction was also observed during the greatest levels of CFVAD support and suggested pronounced effects upon both the right and left ventricle. Collectively, these findings imply that VAD outflow location may have an important role in patient response and recovery. Investigation of the long-term pathophysiologic responses to pump type and outflow location is ongoing.
引用
收藏
页码:432 / 437
页数:6
相关论文
共 22 条
[1]   Effects of right ventricular failure on renal function during pneumatic left ventricular assist [J].
Akamatsu, H ;
Arai, H ;
Sakamoto, T ;
Suzuki, A .
ARTIFICIAL ORGANS, 1996, 20 (03) :240-246
[2]   Relationship of blood pressure and pump flow in an implantable centrifugal blood pump during hypertension [J].
Akimoto, T ;
Yamazaki, K ;
Litwak, P ;
Litwak, KN ;
Tagusari, O ;
Mori, T ;
Antaki, JF ;
Kameneva, MV ;
Watach, MJ ;
Umezu, M ;
Tomioka, J ;
Kormos, RL ;
Koyanagi, H ;
Griffith, BP .
ASAIO JOURNAL, 2000, 46 (05) :596-599
[3]   Comparison of pulsatile and nonpulsatile perfusion of the lung in an extracorporeal large animal model [J].
Brandes, H ;
Albes, JM ;
Conzelmann, A ;
Wehrmann, M ;
Ziemer, G .
EUROPEAN SURGICAL RESEARCH, 2002, 34 (04) :321-329
[4]  
DiGiorgi P. L., 2002, Journal of Heart and Lung Transplantation, V21, P151, DOI 10.1016/S1053-2498(01)00703-3
[5]  
GOODMAN TA, 1976, SURGERY, V80, P31
[6]  
HENDRY PJ, 1994, CIRCULATION, V90, P11353
[7]   Bridging-to-recovery [J].
Hetzer, R ;
Müller, JH ;
Weng, YG ;
Meyer, R ;
Dandel, M .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S109-S113
[8]   Pulsatile and nonpulsatile perfusion: The continuing controversy [J].
Hornick, P ;
Taylor, K .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (03) :310-315
[9]   Smooth muscle cell hypertrophy of renal cortex arteries with chronic continuous flow left ventricular assist [J].
Kihara, S ;
Litwak, KN ;
Nichols, L ;
Litwak, P ;
Kameneva, MV ;
Wu, ZJ ;
Kormos, RL ;
Griffith, BP .
ANNALS OF THORACIC SURGERY, 2003, 75 (01) :178-183
[10]   Effect of pulsatility and hemodynamic power on recovery of renal function [J].
Konishi, H ;
Yland, MJ ;
Brown, M ;
Yamazaki, K ;
Macha, M ;
Konishi, R ;
Kerrigan, JP ;
Zhang, SM ;
Randhawa, PS ;
Antaki, JF ;
Fuse, K ;
Kormos, RL .
ASAIO JOURNAL, 1996, 42 (05) :M720-M723