Noninvasive assessment of respiratory resistance in severe chronic respiratory patients with nasal CPAP

被引:22
作者
Farré, R
Gavela, E
Rotger, M
Ferrer, M
Roca, J
Navajas, D
机构
[1] Univ Barcelona, Fac Med, Lab Biofis & Bioenginyeria, E-08036 Barcelona, Spain
[2] Inst Invest Biomed August Pi Sunyer, Hosp Clin & Prov, Serv Pneumol & Allergia, Barcelona, Spain
关键词
forced oscillation; monitoring; noninvasive ventilation; respiratory impedance;
D O I
10.1034/j.1399-3003.2000.15b16.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Noninvasive measurement of respiratory resistance during nasal ventilatory support could be useful to assess the mechanical status of the patient and to optimize the ventilator settings. The aim was to investigate whether the forced oscillation technique (FOT) applied through a nasal mask allows reliable noninvasive estimation of respiratory resistance (Rrs) in patients with severe chronic respiratory disease, FOT Rrs (5 Hz) and lung resistance (RL) measured simultaneously from spontaneous breathing signals by an oesophageal balloon were compared in eight patients with chronic obstructive pulmonary disease and in sig patients with a restrictive ventilatory defect due to chest wall disease, Measurements were performed in sitting and supine postures during application of nasal continuous positive airway pressure (CPAP): 4, 8 and 12 cmH(2)O in obstructive patients and 4 cmH(2)O in restrictive patients. In the restrictive patients Rrs and RL (in cmH(2)O.s.L-1) were virtually coincident: mean+/-SD, 12.6+/-6.1 and 11.6+/-6.6 (r=0.96) in sitting and 9.7+/-3.1 and 10.2+/-3.3 (r=0.92) in supine posture, respectively, In the obstructive patients (CPAP = 4 cmH(2)O), Rrs slightly underestimated RL: mean+/-SD, 11.5+/-5.9 and 14.1+/-16.8 (r=0.92) in sitting and 15.0+/-9.8 and 21.1+/-12.6 (r=0.96) in supine posture, respectively. Similar results were found at CPAP = 8 and 12 cmH(2)O. The results obtained in patients with resistance values in the range typically found in nasal ventilatory support suggest that forced oscillation technique could be valuable to noninvasively estimate a patient's respiratory mechanical resistance.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 25 条
[1]   PHYSIOLOGICAL-EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE AND MASK PRESSURE SUPPORT DURING EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
APPENDINI, L ;
PATESSIO, A ;
ZANABONI, S ;
CARONE, M ;
GUKOV, B ;
DONNER, CF ;
ROSSI, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (05) :1069-1076
[2]   Forced oscillation technique for the evaluation of severe sleep apnoea hypopnoea syndrome: a pilot study [J].
Badia, JR ;
Farre, R ;
Montserrat, JM ;
Ballester, E ;
Hernandez, L ;
Rotger, M ;
Rodriguez-Roisin, R ;
Navajas, D .
EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (05) :1128-1134
[3]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[4]   EFFECT OF UPPER AIRWAY SHUNT AND SERIES PROPERTIES ON RESPIRATORY IMPEDANCE MEASUREMENTS [J].
CAUBERGHS, M ;
VANDEWOESTIJNE, KP .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) :2274-2279
[5]   OSCILLATION MECHANICS OF LUNGS AND CHEST IN MAN [J].
DUBOIS, AB ;
BRODY, AW ;
LEWIS, DH ;
BURGESS, BF .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 8 (06) :587-594
[6]   HUMAN LUNG IMPEDANCE FROM SPONTANEOUS BREATHING FREQUENCIES TO 32 HZ [J].
FARRE, R ;
PESLIN, R ;
ROTGER, M ;
NAVAJAS, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (03) :1176-1183
[7]   Analog circuit for real-time computation of respiratory mechanical impedance in sleep studies [J].
Farre, R ;
Rotger, M ;
Montserrat, JM ;
Navajas, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (11) :1156-1159
[8]   Inspiratory dynamic obstruction detected by forced oscillation during CPAP - A model study [J].
Farre, R ;
Peslin, R ;
Rotger, M ;
Navajas, D .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (03) :952-956
[9]   A system to generate simultaneous forced oscillation and continuous positive airway pressure [J].
Farre, R ;
Rotger, M ;
Montserrat, JM ;
Navajas, D .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (06) :1349-1353
[10]   FORCED OSCILLATORY IMPEDANCE OF THE RESPIRATORY SYSTEM AT LOW-FREQUENCIES [J].
HANTOS, Z ;
DAROCZY, B ;
SUKI, B ;
GALGOCZY, G ;
CSENDES, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (01) :123-132