Strategies to improve neuroreceptor parameter estimation by linear regression analysis

被引:264
作者
Ichise, M
Toyama, H
Innis, RB
Carson, RE
机构
[1] NIMH, Mol Imaging Branch, Bethesda, MD 20892 USA
[2] NIH, PET Dept, Warren G Magnuson Clin Ctr, Bethesda, MD 20892 USA
关键词
positron emission tomography; graphical analysis; linear regression analysis; parameter estimation; noise-induced bias;
D O I
10.1097/01.WCB.0000038000.34930.4E
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In an attempt to improve neuroreceptor distribution volume (V) estimates, the authors evaluated three alternative linear methods to Logan graphical analysis (GA): GA using total least squares (TLS), and two multilinear analyses, MA1 and MA2, based on mathematical rearrangement of GA equation and two-tissue compartments, respectively, using simulated and actual PET data of two receptor tracers, [F-18]FCWAY and [C-11]MDL 100,907. For simulations, all three methods decreased the noise-induced GA bias (up to 30%) at the expense of increased variability. The bias reduction was most pronounced for MA1, moderate to large for MA2, and modest to moderate for TLS. In addition, GA, TLS, and MA1, methods that used only a portion of the data (T > t*, chosen by an automatic process), showed a small V underestimation for [C-11]MDL 100,907 with its slow kinetics, due to selection of t* before the true point of linearity. These noniterative methods are computationally simple, allowing efficient pixelwise parameter estimation. For tracers with kinetics that permit t* to be accurately identified within the study duration, MA1 appears to be the best. For tracers with slow kinetics and low to moderate noise, however, MA2 may provide the lowest bias while maintaining computational ease for pixelwise parameter estimation.
引用
收藏
页码:1271 / 1281
页数:11
相关论文
共 22 条
[2]  
Burger C, 1997, J NUCL MED, V38, P1818
[3]  
CARSON R E, 1986, P347
[4]   COMPARISON OF BOLUS AND INFUSION METHODS FOR RECEPTOR QUANTITATION - APPLICATION TO [F-18] CYCLOFOXY AND POSITRON EMISSION TOMOGRAPHY [J].
CARSON, RE ;
CHANNING, MA ;
BLASBERG, RG ;
DUNN, BB ;
COHEN, RM ;
RICE, KC ;
HERSCOVITCH, P .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (01) :24-42
[5]  
CARSON RE, 1993, INT CONGR SER, V1030, P499
[6]   PET evaluation of [18F]FCWAY, an analog of the 5-HT1A receptor antagonist, WAY-100635 [J].
Carson, RE ;
Lan, LX ;
Watabe, H ;
Der, MG ;
Adams, HR ;
Jagoda, E ;
Herscovitch, P ;
Eckelman, WC .
NUCLEAR MEDICINE AND BIOLOGY, 2000, 27 (05) :493-497
[7]  
CARSON RE, 2000, NEUROIMAGE, V11, pS45
[8]  
EVANS AC, 1987, J CEREB BLOOD FLO S1, V7, pS453
[9]   A STUDY ON STATISTICALLY RELIABLE AND COMPUTATIONALLY EFFICIENT ALGORITHMS FOR GENERATING LOCAL CEREBRAL BLOOD-FLOW PARAMETRIC IMAGES WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, DG ;
WANG, ZZ ;
HUANG, SC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :182-188
[10]   An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation [J].
Feng, DG ;
Huang, SC ;
Wang, ZZ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (04) :512-518