Characterization of Ti-6Al-4V modified by nitrogen plasma immersion ion implantation

被引:26
作者
Alonso, F [1 ]
Rinner, M [1 ]
Loinaz, A [1 ]
Onate, JI [1 ]
Ensinger, W [1 ]
Rauschenbach, B [1 ]
机构
[1] UNIV AUGSBURG,INST PHYS,D-86135 AUGSBURG,GERMANY
关键词
friction; load bearing capacity; plasma immersion ion implantation; Ti-6Al-4V; wear;
D O I
10.1016/S0257-8972(97)00065-0
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Ti-6Al-4V alloy is commonly used in biomedical or aerospace applications, due to its excellent combination of chemical and mechanical properties, such as bioinertness, corrosion resistance or high strength to weight ratio. The use of surface treatments or coatings has widened the application possibilities of this alloy. The often observed poor tribological performance can be overcome by the correct choice of surface: engineering methods. Ion implantation is a candidate among the different available processes and excellent results have been obtained in biomedical applications. However, when complex geometries are involved, it can be a difficult and less economically effective treatment. Plasma immersion ion implantation (PIII) offers the possibility of performing three-dimensional ion beam treatments, reducing the need for manipulation under vacuum to obtain a uniform treatment of geometrically complex parts. In this work, PIII was used to implant nitrogen in the Ti-6Al-4V alloy. The nitrogen plasma was generated with a 2.45 GHz microwave excitation, and a pulsed bias voltage of 45 kV with pulse repetition rates of 50 and 400 Hz were applied. Nitrogen retained doses were evaluated by means crf Rutherford backscattering spectroscopy (RES). Pin-on-disc wear and friction tests were performed on the implanted samples. An ultra high molecular weight polyethylene pin was used as the counterface material to partially simulate the conditions encountered in biomedical applications. A reasonable improvement in load bearing capacity with respect to the unimplanted alloy was observed after these tribological tests. However, no hardening could be measured after ion implantation. The worn surfaces were observed by scanning electron microscopy and optical profilometry after the tests and the type of wear mechanism was studied. The effect of the implantation was to increase the load at which breakthrough occurred on the protective surface layer. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:305 / 308
页数:4
相关论文
共 21 条
[1]   Mechanical properties and structure of Ti-6Al-4V alloy implanted with different light ions [J].
Alonso, F. ;
Arizaga, A. ;
Quainton, S. ;
Ugarte, J. J. ;
Viviente, J. L. ;
Onate, J. I. .
SURFACE & COATINGS TECHNOLOGY, 1995, 74-75 (1-3) :986-992
[2]   Effects of ion implantation on Ti-6Al-4V on its frictional behaviour against UHMWPE [J].
Alonso, F ;
Ugarte, JJ ;
Sansom, D ;
Viviente, JL ;
Onate, JI .
SURFACE & COATINGS TECHNOLOGY, 1996, 83 (1-3) :301-306
[3]   SURFACE MODIFICATION OF TI-6A1-4V SURGICAL ALLOY BY PLASMA SOURCE ION-IMPLANTATION [J].
CHEN, A ;
SRIDHARAN, K ;
CONRAD, JR ;
FETHERSTON, RP .
SURFACE & COATINGS TECHNOLOGY, 1991, 50 (01) :1-4
[4]  
CHEN A, 1991, WEAR MATERIALS, P667
[5]   Development of a plasma immersion ion implanter for the surface treatment of metal components [J].
Collins, GA ;
Hutchings, R ;
Short, KT ;
Tendys, J ;
VanDerValk, CH .
SURFACE & COATINGS TECHNOLOGY, 1996, 84 (1-3) :537-543
[6]   ION-BEAM ASSISTED COATING AND SURFACE MODIFICATION WITH PLASMA SOURCE ION-IMPLANTATION [J].
CONRAD, JR ;
DODD, RA ;
HAN, S ;
MADAPURA, M ;
SCHEUER, J ;
SRIDHARAN, K ;
WORZALA, FJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (04) :3146-3151
[7]   PLASMA SOURCE ION-IMPLANTATION DOSE UNIFORMITY OF A 2X2 ARRAY OF SPHERICAL TARGETS [J].
CONRAD, JR ;
BAUMANN, S ;
FLEMING, R ;
MEEKER, GP .
JOURNAL OF APPLIED PHYSICS, 1989, 65 (04) :1707-1712
[10]  
Ensinger W, 1996, MATER RES SOC SYMP P, V396, P521