Development of a homogeneous immunoassay for the detection of angiotensin I in plasma using AlphaLISA acceptor beads technology

被引:48
作者
Cauchon, Elizabeth [1 ]
Liu, Susana [2 ]
Percival, M. David [1 ]
Rowland, Steve E. [2 ]
Xu, Daigen [2 ]
Binkert, Christoph [3 ]
Strickner, Panja [3 ]
Falgueyret, Jean-Pierre [1 ]
机构
[1] Merck Frosst Ctr Therapeut Res, Dept Biochem & Mol Biol, Kirkland, PQ H9H 3L1, Canada
[2] Merck Frosst Ctr Therapeut Res, Dept Pharmacol, Kirkland, PQ H9H 3L1, Canada
[3] Actel Pharmaceut, CH-4123 Allschwil, Switzerland
关键词
AlphaScreen; Angiotensin; Enzyme immunoassay; Luminescent oxygen channeling immunoassay; PRA; PRC; Renin; OXYGEN CHANNELING IMMUNOASSAY; RENIN INHIBITION; RATS; MICE;
D O I
10.1016/j.ab.2009.02.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Plasma renin activity (PRA) is a well-established biomarker for assessing the efficacy of various antihypertensive agents Such as direct renin inhibitors, angiotensin receptor blockers, and angiotensin-converting enzyme inhibitors (ACEIs). PRA measurements are obtained through the detection and quantification of angiotensin I (Ang I) produced by the action of renin on its natural Substrate angiotensinogen. The most accepted and reproducible method For PRA measurement uses an antibody capture Ang I methodology that employs specific antibodies that recognize and protect Ang I against angiotensinase activities contained in plasma. The amount of Ang I is then quantified by either radioimmunoassay (RIA) or enzyme immunoassay (EIA). In the current report, we describe the optimization of a novel homogeneous immunoassay based on the AlphaScreen technology for the detection and quantification of antibody-captured Ang I using AlphaLISA acceptor beads in buffer and in the plasma Of Various species (human, tat, and mouse). Ex vivo measurements of renin activity were performed using 10 mu l or less of a reaction mixture, and concentrations as low as I nM Ang I were quantified. Titration Curves obtained for the quantification of Ang I in buffer and plasma gave similar EC50 values of 5.6 and 14.4 nM respectively. Both matrices generated an equivalent dynamic range that varies from approximately 1 to 50 nM. Renin inhibitors have been Successfully titrated and IC50 values obtained correlated well with those obtained Using EIA methodology (r(2) = 0.80). This assay is sensitive, robust, fast, and less tedious than measurements performed using nonhomogeneous EIA. The AlphaLISA methodology is homogeneous, does not require wash steps prior to the addition of reagents, and does not generate radioactive waste. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 15 条
[1]  
Agnoli G. C., 1996, Bollettino Societa Italiana Biologia Sperimentale, V72, P109
[2]   The renin-angiotensin aldosterone system: Pathophysiological role and pharmacologic inhibition [J].
Atlas, Steven A. .
JOURNAL OF MANAGED CARE PHARMACY, 2007, 13 (08) :S9-S20
[3]   RETRACTED: Direct renin inhibition: clinical pharmacology (Retracted article. See vol. 90, pg. 465, 2012) [J].
Azizi, Michel .
JOURNAL OF MOLECULAR MEDICINE-JMM, 2008, 86 (06) :647-654
[4]   Current concepts: renin inhibition in the treatment of hypertension [J].
Gradman, Alan H. ;
Pinto, Rekha ;
Kad, Rishi .
CURRENT OPINION IN PHARMACOLOGY, 2008, 8 (02) :120-126
[5]   Regulation of renin secretion and expression in mice deficient in ß1-and ß2-adrenergic receptors [J].
Kim, Soo Mi ;
Chen, Limeng ;
Faulhaber-Walter, Robert ;
Oppermann, Mona ;
Huang, Yuning ;
Mizel, Diane ;
Briggs, Josephine P. ;
Schnermann, Jurgen .
HYPERTENSION, 2007, 50 (01) :103-109
[6]   Low plasma renin and reduced renin secretory responses to acute stimuli in conscious COX-2-deficient mice [J].
Kim, Soo Mi ;
Chen, Limeng ;
Mizel, Diane ;
Huang, Yuning G. ;
Briggs, Josie P. ;
Schnermann, Jurgen .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2007, 292 (01) :F415-F422
[7]   Low birth weight in response to salt restriction during pregnancy is not due to alterations in uterine-placental blood flow or the placental and peripheral renin-angiotensin system [J].
Leandro, Sandra Marcia ;
Shinohara Furukawa, Luzia Naoko ;
Massola Shimizu, Maria Heloisa ;
Casarini, Dulce Elena ;
Seguro, Antonio Carlos ;
Patriarca, Giuliana ;
Coelho, Michella Soares ;
Dolnikoff, Miriam Sterman ;
Heimann, Joel Claudio .
PHYSIOLOGY & BEHAVIOR, 2008, 95 (1-2) :145-151
[8]   Regulation of plasma vasopressin and renin activity in conscious hindlimb-unloaded rats [J].
Mueller, Patrick J. ;
Sullivan, Margaret J. ;
Grindstaff, Regina R. ;
Cunningham, J. Thomas ;
Hasser, Eileen M. .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2006, 291 (01) :R46-R52
[9]   A luminescent oxygen channeling immunoassay for the determination of insulin in human plasma [J].
Poulsen, Fritz ;
Jensen, Kirsten Borres .
JOURNAL OF BIOMOLECULAR SCREENING, 2007, 12 (02) :240-247
[10]   EASY RADIOIMMUNOLOGICAL MICROASSAY OF RENIN-ACTIVITY, CONCENTRATION AND SUBSTRATE IN HUMAN AND ANIMAL PLASMA AND TISSUES BASED ON ANGIOTENSIN-I TRAPPING BY ANTIBODY [J].
POULSEN, K ;
JORGENSEN, J .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1974, 39 (05) :816-825