Comparative LC-MS and HPLC analyses of selected antiepileptics and beta-blocking drugs

被引:45
作者
Abdel-Hamid, ME [1 ]
机构
[1] Kuwait Univ, Dept Pharmaceut Chem, Fac Pharm, Safat 13110, Kuwait
来源
FARMACO | 2000年 / 55卷 / 02期
关键词
LC-MS; HPLC; antiepileptics; beta-blocking drugs; pharmaceutical products;
D O I
10.1016/S0014-827X(00)00006-9
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A highly sensitive and specific assay procedure based on the combination of liquid chromatography and mass spectrometry (LC-MS) has been developed for the quantitative analysis of selected antiepileptics (carbamazepine and phenytoin) and beta-blocking drugs (acebutolol, atenolol, pindolol and propranolol) using APCI as an ionization process. The measured concentration range was 100-300 ng ml(-1) for all drugs except phenytoin (0.5-1.5 mu g ml(-1)). Analysis was based on direct injection of methanolic solutions of drugs into the mass spectrometer with the subsequent elution with a mobile phase consisting of methanol and 1% acetic acid solution (4:1) at a flow rate 1 mi min(-1). The mass spectrometer was programmed to permit detection and determination of either fragment or molecular ions of carbamazepine, phenytoin, acebutolol, atenolol, pindolol and propranolol at m/e 194.3, 252.9, 337.2, 267.1, 249.1 and 260.1, respectively. The recorded chromatograms exhibited well-resolved peaks at retention times < 1 min. The peak area was correlated linearly to the drug concentration. Intraday precision gave relative standard deviations in the range 1.75-4.02%. Compared to HPLC, the described LC-MS was faster, more sensitive and specific. Unlike HPLC, LC-MS could be applied to analyze incompletely resolved mixtures. The absolute detection limits for LC-MS and HPLC were 0.2-0.5 and 10-25 ng, respectively. Recovery studies of the investigated compounds in pharmaceutical products using LC-MS and HPLC gave mean percentages of 97.5-102.0 and 98.4-103.3, respectively. Statistical analysis of the data using t- and F-tests showed insignificant differences between both methods for the analysis of carbamazepine, phenytoin, acebutolol and atenolol in pharmaceutical formulations. However, LC-MS gave more accurate results than HPLC for determination of pindolol in tablets. Propranolol could only be determined in tablets using LC-MS. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:136 / 145
页数:10
相关论文
共 21 条
[2]  
[Anonymous], FENXI HUAXUE
[3]   Simultaneous determination of phenytoin, carbamazepine, and 10,11-carbamazepine epoxide in human plasma by high-performance liquid chromatography with ultraviolet detection [J].
Bhatti, MM ;
Hanson, GD ;
Schultz, L .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (07) :1233-1240
[4]   High-speed liquid chromatographic method for the monitoring of carbamazepine and its active metabolite, carbamazepine-10,11-epoxide, in human plasma [J].
Chollet, D ;
Castella, E ;
Combe, P ;
Arnera, V .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 683 (02) :237-243
[5]   Analysis of nifedipine acebutolol hydrochloride binary combination in tablets using UV-derivative spectroscopy, capillary gas chromatography and high performance liquid chromatography [J].
ElWalily, AFM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (01) :21-30
[6]   Simultaneous determination of phenobarbital and phenytoin in tablet preparations by multivariate spectrophotometric calibration [J].
Goicoechea, HC ;
Olivieri, AC .
TALANTA, 1998, 47 (01) :103-108
[7]  
Hallbach J, 1997, EUR J CLIN CHEM CLIN, V35, P755
[8]  
Hanada A. K., 1996, INDIAN DRUGS, V33, P559
[9]  
HUANG HL, 1999, FENXI CESHI XUEBAO, V18, P45
[10]   Extraction-spectrophotometric determination of phenytoin in capsules and plasma using potassium permanganate/dicyclohexano-24-crown-8 [J].
Korany, MA ;
Bedair, MM ;
Haggag, RS .
TALANTA, 1998, 46 (01) :9-14