Comparative LC-MS and HPLC analyses of selected antiepileptics and beta-blocking drugs

被引:45
作者
Abdel-Hamid, ME [1 ]
机构
[1] Kuwait Univ, Dept Pharmaceut Chem, Fac Pharm, Safat 13110, Kuwait
来源
FARMACO | 2000年 / 55卷 / 02期
关键词
LC-MS; HPLC; antiepileptics; beta-blocking drugs; pharmaceutical products;
D O I
10.1016/S0014-827X(00)00006-9
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A highly sensitive and specific assay procedure based on the combination of liquid chromatography and mass spectrometry (LC-MS) has been developed for the quantitative analysis of selected antiepileptics (carbamazepine and phenytoin) and beta-blocking drugs (acebutolol, atenolol, pindolol and propranolol) using APCI as an ionization process. The measured concentration range was 100-300 ng ml(-1) for all drugs except phenytoin (0.5-1.5 mu g ml(-1)). Analysis was based on direct injection of methanolic solutions of drugs into the mass spectrometer with the subsequent elution with a mobile phase consisting of methanol and 1% acetic acid solution (4:1) at a flow rate 1 mi min(-1). The mass spectrometer was programmed to permit detection and determination of either fragment or molecular ions of carbamazepine, phenytoin, acebutolol, atenolol, pindolol and propranolol at m/e 194.3, 252.9, 337.2, 267.1, 249.1 and 260.1, respectively. The recorded chromatograms exhibited well-resolved peaks at retention times < 1 min. The peak area was correlated linearly to the drug concentration. Intraday precision gave relative standard deviations in the range 1.75-4.02%. Compared to HPLC, the described LC-MS was faster, more sensitive and specific. Unlike HPLC, LC-MS could be applied to analyze incompletely resolved mixtures. The absolute detection limits for LC-MS and HPLC were 0.2-0.5 and 10-25 ng, respectively. Recovery studies of the investigated compounds in pharmaceutical products using LC-MS and HPLC gave mean percentages of 97.5-102.0 and 98.4-103.3, respectively. Statistical analysis of the data using t- and F-tests showed insignificant differences between both methods for the analysis of carbamazepine, phenytoin, acebutolol and atenolol in pharmaceutical formulations. However, LC-MS gave more accurate results than HPLC for determination of pindolol in tablets. Propranolol could only be determined in tablets using LC-MS. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:136 / 145
页数:10
相关论文
共 21 条
[11]   THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF POLAR BETA-BLOCKING DRUGS - PRELIMINARY-RESULTS [J].
LELOUX, MS ;
NIESSEN, WMA ;
VANDERHOEVEN, RAM .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (10) :647-649
[12]   Sensitive determination of erythromycin in human plasma by LC-MS/MS [J].
Li, YX ;
Neufeld, K ;
Chastain, J ;
Curtis, A ;
Velagaleti, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (06) :961-970
[13]   Determination of 2-chlorodeoxyadenosine (cladribine, 2-CdA) in human plasma by liquid chromatography atmospheric pressure chemical ionization mass spectrometry [J].
Moyer, MD ;
Johannsen, T ;
Stubbs, RJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (01) :45-51
[14]  
NASIEROWSKA Z, 1984, FARM POL, V40, P87
[15]  
Panchagnula R., 1998, Pharmacy and Pharmacology Communications, V4, P401
[16]   SIMULTANEOUS DETERMINATION OF CLOPAMIDE-PINDOLOL COMBINATION IN TABLETS BY ZERO-CROSSING DERIVATIVE SPECTROPHOTOMETRY [J].
PANDERI, I ;
PARISSIPOULOU, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (02) :151-156
[17]   Isocratic, simultaneous reversed-phase high-performance liquid chromatographic estimation of six drugs for combined hypertension therapy [J].
Patel, YP ;
Patil, S ;
Bhoir, IC ;
Sundaresan, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :283-286
[18]   Simultaneous determination of amiloride HCl, hydrochlorothiazide and atenolol in combined formulations by derivative spectroscopy [J].
Prasad, CVN ;
Parihar, C ;
Sunil, K ;
Parimoo, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) :877-884
[19]   Simultaneous determination of propranolol and pindolol by synchronous spectrofluorimetry [J].
Ruiz, TP ;
Martinez-Lozano, C ;
Tomas, V ;
Carpena, J .
TALANTA, 1998, 45 (05) :969-976
[20]   Charge-transfer complexes of barbiturates and phenytoin [J].
Saleh, GA .
TALANTA, 1998, 46 (01) :111-121