Application of bead array technology to simultaneous detection of human leucocyte antigen and human platelet antigen antibodies

被引:33
作者
Fujiwara, K. [1 ]
Shimano, K. [1 ]
Tanaka, H. [1 ]
Sekine, M. [1 ]
Kashiwase, K. [1 ]
Uchikawa, M. [1 ]
Satake, M. [1 ]
Nakajima, K. [1 ]
机构
[1] Japanese Red Cross Tokyo Blood Ctr, Dept Lab, Koto Ku, Tokyo 1358639, Japan
关键词
bead array; flow cytometric analysis; high-throughput; HLA antibodies; HPA antibodies; ACUTE LUNG INJURY; HLA CLASS-I; FLOW-CYTOMETRY; IMMOBILIZATION; PEPTIDES; ASSAY; CELL;
D O I
10.1111/j.1423-0410.2008.01140.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Detection of antibodies against human leucocyte antigens (HLA) and human platelet antigens (HPA) is crucial for patients refractory to platelet transfusion therapy. However, a reliable and high-throughput method for HLA cross-matching and detecting HPA antibodies has not yet been described. Immunocomplex capture fluorescence analysis (ICFA) was developed for high-throughput, simultaneous detection of HLA and HPA antibodies. Microarray beads were separately coupled with monoclonal antibodies specific for CD36, CD41, CD42b, CD49b, CD61 and HLA class I antigens. Platelets reacting with patient serum were lysed and the lysates were incubated with the bead mixture to specifically capture antigen-antibody complexes via the epitopes on platelet glycoproteins or HLA antigens. The beads capturing immunocomplexes were then subjected to flow cytometric analysis. Immunocomplex capture fluorescence analysis was validated using 50 serum samples containing HLA antibodies and 20 serum samples containing HPA antibodies. The method enabled the detection of all the HLA antibodies with a sensitivity comparable to that of the purified HLA antigen-coated pooled-bead assay (FlowPRA, One Lambda, Canoga Park, CA, USA). The method also enabled the detection of all the HPA antibodies with a sensitivity higher than that of the mixed passive haemagglutination. In this study, we developed a rapid, simple and reliable method for the simultaneous analysis of HLA and HPA antibodies. ICFA can also be used as an alternative to the lymphocyte cytotoxicity test for HLA cross-matching.
引用
收藏
页码:244 / 251
页数:8
相关论文
共 17 条
[1]   THE FLOW CYTOMETRIC CROSSMATCH - DUAL-COLOR ANALYSIS OF T-CELL AND B-CELL REACTIVITIES [J].
BRAY, RA ;
LEBECK, LK ;
GEBEL, HM .
TRANSPLANTATION, 1989, 48 (05) :834-840
[2]   A modified rapid monoclonal antibody-specific immobilization of platelet antigen assay for the detection of human platelet antigen (HPA) antibodies: a multicentre evaluation [J].
Campbell, K. ;
Rishi, K. ;
Howkins, G. ;
Gilby, D. ;
Mushens, R. ;
Ghevaert, C. ;
Metcalfe, P. ;
Ouwehand, W. H. ;
Lucas, G. .
VOX SANGUINIS, 2007, 93 (04) :289-297
[3]  
Cook D J, 1987, Clin Transpl, P409
[4]   HLA class I epitopes: Recognition of binding sites by mAbs or eluted alloantibody confirmed with single recombinant antigens [J].
El-Awar, Nadim ;
Lee, Jar-How ;
Tarsitani, Christine ;
Terasaki, Paul I. .
HUMAN IMMUNOLOGY, 2007, 68 (03) :170-180
[5]  
GAROVOY MR, 1983, TRANSPLANT P, V15, P1939
[6]  
KIEFEL V, 1987, BLOOD, V70, P1722
[7]  
LeFor WM, 1996, CLIN TRANSPLANT, V10, P601
[8]   Nomenclature of human platelet antigens [J].
Metcalfe, P ;
Watkins, NA ;
Ouwehand, WH ;
Kaplan, C ;
Newman, P ;
de Haas, M ;
Aster, R ;
Shibata, Y ;
Smith, J ;
Kiefel, V ;
Santoso, S .
VOX SANGUINIS, 2003, 85 (03) :240-245
[9]   Flow cytometric detection of HLA antibodies using a spectrum of microbeads [J].
Pei, R ;
Lee, JH ;
Chen, T ;
Rojo, S ;
Terasaki, PI .
HUMAN IMMUNOLOGY, 1999, 60 (12) :1293-1302
[10]   Simultaneous HLA class I and class II antibodies screening with flow cytometry [J].
Pei, R ;
Wang, G ;
Tarsitani, C ;
Rojo, S ;
Chen, T ;
Takemura, S ;
Liu, A ;
Lee, J .
HUMAN IMMUNOLOGY, 1998, 59 (05) :313-322