Evaluation and utilization of preassembled frozen commercial fast real-time qPCR master mixes for detection of cytomegalovirus and BK virus

被引:2
作者
Glover, William A. [1 ]
Atienza, Ederlyn E. [1 ]
Nesbitt, Shannon [1 ]
Kim, Woo J. [1 ]
Castor, Jared [1 ]
Cook, Linda [1 ]
Jerome, Keith R. [1 ,2 ]
机构
[1] Univ Washington, Dept Lab Med, Mol Virol Lab, Seattle, WA 98195 USA
[2] Fred Hutchinson Canc Res Ctr, Vaccine & Infect Dis Div, Seattle, WA 98104 USA
关键词
preassembled; frozen; qPCR; CMV; BKV; efficiency; REVERSE TRANSCRIPTION-PCR; QUANTITATION; NEPHROPATHY; DIAGNOSIS; REAGENTS; LOAD;
D O I
10.1002/jmv.24303
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Quantitative DNA detection of cytomegalovirus (CMV) and BK virus (BKV) is critical in the management of transplant patients. Quantitative laboratory-developed procedures for CMV and BKV have been described in which much of the processing is automated, resulting in rapid, reproducible, and high-throughput testing of transplant patients. To increase the efficiency of such assays, the performance and stability of four commercial preassembled frozen fast qPCR master mixes (Roche FastStart Universal Probe Master Mix with Rox, Bio-Rad SsoFast Probes Supermix with Rox, Life Technologies TaqMan FastAdvanced Master Mix, and Life Technologies Fast Universal PCR Master Mix), in combination with in-house designed primers and probes, was evaluated using controls and standards from standard CMV and BK assays. A subsequent parallel evaluation using patient samples was performed comparing the performance of freshly prepared assay mixes versus aliquoted frozen master mixes made with two of the fast qPCR mixes (Life Technologies TaqMan FastAdvanced Master Mix, and Bio-Rad SsoFast Probes Supermix with Rox), chosen based on their performance and compatibility with existing PCR cycling conditions. The data demonstrate that the frozen master mixes retain excellent performance over a period of at least 10 weeks. During the parallel testing using clinical specimens, no difference in quantitative results was observed between the preassembled frozen master mixes and freshly prepared master mixes. Preassembled fast real-time qPCR frozen master mixes perform well and represent an additional strategy laboratories can implement to reduce assay preparation times, and to minimize technical errors and effort necessary to perform clinical PCR. J. Med. Virol. 88:115-119, 2016. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 13 条
[1]   Optimization of quantitative detection of cytomegalovirus DNA in plasma by real-time PCR [J].
Boeckh, M ;
Huang, M ;
Ferrenberg, J ;
Stevens-Ayers, T ;
Stensland, L ;
Nichols, WG ;
Corey, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (03) :1142-1148
[2]  
Cobo Fernando, 2012, Open Virol J, V6, P103, DOI 10.2174/1874357901206010103
[3]   Use of the MagNA pure LC automated nucleic acid extraction system followed by real-time reverse transcription-PCR for ultrasensitive quantitation of hepatitis C virus RNA [J].
Cook, L ;
Ng, KW ;
Bagabag, A ;
Corey, L ;
Jerome, KR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (09) :4130-4136
[4]   Development of an internal positive control for rapid diagnosis of avian influenza virus infections by real-time reverse transcription-PCR with lyophilized reagents [J].
Das, Arnaresh ;
Spackman, Erica ;
Senne, Dennis ;
Pedersen, Jan ;
Suarez, David L. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (09) :3065-3077
[5]   Marked variability of BK virus load measurement using quantitative real-time PCR among commonly used assays [J].
Hoffman, Noah G. ;
Cook, Linda ;
Atienza, Ederlyn E. ;
Limaye, Ajit P. ;
Jerome, Keith R. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (08) :2671-2680
[6]   Treatment of refractory BK virus-associated nephropathy with cidofovir [J].
Kadambi, PV ;
Josephson, MA ;
Williams, J ;
Corey, L ;
Jerome, KR ;
Meehan, SM ;
Limaye, AP .
AMERICAN JOURNAL OF TRANSPLANTATION, 2003, 3 (02) :186-191
[7]   Simplified PCR set-up using a frozen preformulated mix for the detection of cytomegalovirus [J].
Kofler, B ;
Klausegger, A .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1999, 34 (01) :33-35
[8]   Quantitation of BK virus load in serum for the diagnosis of BK virus-associated nephropathy in renal transplant recipients [J].
Limaye, AP ;
Jerome, KR ;
Kuhr, CS ;
Ferrenberg, J ;
Huang, ML ;
Davis, CL ;
Corey, L ;
Marsh, CL .
JOURNAL OF INFECTIOUS DISEASES, 2001, 183 (11) :1669-1672
[9]   Modifications of Commercial Toxigenic Clostridium difficile PCR Resulting in Improved Economy and Workflow Efficiency [J].
Munson, Erik ;
Bilbo, Dorothy ;
Paul, Mary ;
Napierala, Maureen ;
Hryciuk, Jeanne E. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (06) :2279-2282
[10]   Cost- Effective Modification of a Commercial PCR Assay for Detection of Methicillin-Resistant or -Susceptible Staphylococcus aureus in Positive Blood Cultures [J].
Munson, Erik ;
Kramme, Timothy ;
Culver, Anne ;
Hryciuk, Jeanne E. ;
Schell, Ronald F. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) :1408-1412