Gamma and beta intra-operative imaging probes

被引:23
作者
Hoffman, EJ
Tornai, MP
Levin, CS
MacDonald, LR
Siegel, S
机构
[1] UNIV CALIF LOS ANGELES,DEPT PHYS,LOS ANGELES,CA 90095
[2] NATL INST HLTH,DEPT NUCL MED,BETHESDA,MD 20892
关键词
D O I
10.1016/S0168-9002(97)00247-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Small area (similar to 1.5 cm(2)) scintillation cameras for imaging gammas and betas using inter-changeable detector front ends were built and characterized. Components common to both emission imaging cameras include: (1) fiber optic bundles 2-3m long, comprised of multi-clad fibers which connect the scintillation detector to (2) an MC-PMT; (3) parallel MC-PMT outputs feed a resistive positioning network and i-V converter/line driver network which produce balanced X+, X-, Y+, and Y- outputs; and (4) four ADCs and a Macintosh PC for system control and image display. The beta and gamma devices used distinct scintillation detectors which were characterized by both simulation and measurement. The beta camera utilized a 0.5 mm by 1.25 cm phi CaF2(Eu) scintillation crystal coupled, through a diffusing light guide, to 19 2-mm phi optical fibers. These front-end fibers are in turn coupled by a more flexible fiber bundle to the MC-PMT. CaF2(Eu) has high light output, high beta sensitivity, and low gamma sensitivity. Image signals are histogrammed and displayed after Anger logic computations are performed on digitized signals. The beta camera has <0.6mm FWHM intrinsic resolution. The gamma camera concept was tested with matrices of discrete 1 x 1 mm(2) and 2 x 2 mm(2) CsI(Tl) and NaI(TI) crystals of various lengths, and 3 mm thick continuous crystals. Configurations using 4 x 4 element matrices with one-to-one coupling between crystals and fiber channels, and light diffusers between each crystal matrix and fibers were evaluated. The continuous crystals were coupled directly to the fiber optics with signal and data processing analogous to the beta camera. Coupling of discrete crystals to fiber optics by both methods gave essentially perfect identification of the crystal of interaction, allowing spatial resolution to be defined by the crystal size and collimator. The continuous crystal gamma camera gave intrinsic resolution of similar to 1.4mm FWHM.
引用
收藏
页码:324 / 329
页数:6
相关论文
共 18 条
[1]   DEVELOPMENT OF SMALL INVIVO IMAGING PROBES FOR TUMOR-DETECTION [J].
BARBER, HB ;
BARRETT, HH ;
WILD, WJ ;
WOOLFENDEN, JM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :599-604
[2]   THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS [J].
BIRD, AJ ;
CARTER, T ;
DEAN, AJ ;
RAMSDEN, D ;
SWINYARD, BM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :395-399
[3]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[4]   AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :264-272
[5]  
HARTSOUGH NE, 1989, P SOC PHOTO-OPT INS, V1068, P92
[6]   LIGHT COLLECTION IN SCINTILLATION DETECTOR COMPOSITES FOR NEUTRON DETECTION [J].
KNOLL, GF ;
KNOLL, TF ;
HENDERSON, TM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :872-875
[7]   Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use [J].
Levin, CS ;
MacDonald, LR ;
Tornai, MP ;
Hoffman, EJ ;
Park, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :2053-2060
[8]   INVESTIGATION OF THE PHYSICAL ASPECTS OF BETA-IMAGING PROBES USING SCINTILLATING FIBERS AND VISIBLE-LIGHT PHOTON COUNTERS [J].
MACDONALD, LR ;
TORNAI, MP ;
LEVIN, CS ;
PARK, J ;
ATAC, M ;
CLINE, DB ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1351-1357
[9]  
MACDONALD LR, 1995, P SOC PHOTO-OPT INS, V2551, P92, DOI 10.1117/12.218645
[10]   Mercuric iodide photodetector arrays for gamma-ray imaging [J].
Patt, BE ;
Iwanczyk, JS ;
Wang, YJ ;
Tornai, MP ;
Levin, CS ;
Hoffman, EJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :295-300