Calibration transfer from sample cell to fiber-optic probe

被引:29
作者
Chen, CS
Brown, CW
Lo, SC
机构
[1] UNIV RHODE ISL,DEPT CHEM,KINGSTON,RI 02881
[2] US TOBACCO CO,DEPT RES & DEV,NASHVILLE,TN 37203
关键词
multivariate calibration; multicomponent analysis; calibration transfer; Fourier transform;
D O I
10.1366/0003702971940927
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
A calibration transfer method, piecewise direct standardization (PDS), was applied to a set of two-component samples measured on the same UV-visible spectrometer with the use of a cuvette cell with a 10-mm pathlength and a fiber-optic probe with a 2-mm pathlength, Piecewise direct standardization proceeds by determining a structured transformation matrix using the spectra of a few samples measured with both devices. This transformation matrix can then be used to transform any spectrum measured on one device to that obtained on another device, thereby making the calibration model transferable between devices. We used the spectra measured in a cuvette as the standard set and transferred the calibration model obtained for these spectra to spectra measured with a 2-mm fiber-optic probe on the same instrument. The total standard error of prediction (SEP) for the fiber-optic probe was 5.84 before the calibration transfer and 1.87 afterwards. Spectra were also processed by taking the Fourier transform prior to the calibration transfer, The 512 data points in each spectrum were compressed to 32 terms, starting with the first term after the dc offset. This processing reduced the background and the noise, As a consequence, in the Fourier domain, the total SEP was 5.69 before the calibration standardization and 0.79 after the calibration standardization. A calibration transfer was also performed between two fiber-optic probes; the total SEP in the spectral domain was 2.16 prior to the transfer and 1.04 after the transfer, whereas in the Fourier domain the SEP was 1.50 prior to the transfer and 0.77 after the transfer.
引用
收藏
页码:744 / 748
页数:5
相关论文
共 13 条
[1]
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]
A DRUG DISSOLUTION MONITOR EMPLOYING MULTIPLE FIBER OPTIC PROBES AND A UV/VISIBLE DIODE-ARRAY SPECTROPHOTOMETER [J].
CHEN, CS ;
BROWN, CW .
PHARMACEUTICAL RESEARCH, 1994, 11 (07) :979-983
[3]
MULTIVARIATE CALIBRATION STANDARDIZATION [J].
DENOORD, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) :85-97
[4]
MULTICOMPONENT ANALYSIS USING FOURIER-TRANSFORM INFRARED AND UV SPECTRA [J].
DONAHUE, SM ;
BROWN, CW ;
OBREMSKI, RJ .
APPLIED SPECTROSCOPY, 1988, 42 (02) :353-359
[5]
SUCCESSIVE AVERAGE ORTHOGONALIZATION OF SPECTRAL DATA [J].
DONAHUE, SM ;
BROWN, CW .
ANALYTICAL CHEMISTRY, 1991, 63 (10) :980-985
[6]
RECENT DEVELOPMENTS IN MULTIVARIATE CALIBRATION [J].
KOWALSKI, BR ;
SEASHOLTZ, MB .
JOURNAL OF CHEMOMETRICS, 1991, 5 (03) :129-145
[7]
NEAR-IR FIBEROPTIC TEMPERATURE SENSOR [J].
LIN, J ;
BROWN, CW .
APPLIED SPECTROSCOPY, 1993, 47 (01) :62-68
[8]
CALIBRATION TRANSFER AND MEASUREMENT STABILITY OF NEAR-INFRARED SPECTROMETERS [J].
WANG, YD ;
KOWALSKI, BR .
APPLIED SPECTROSCOPY, 1992, 46 (05) :764-771
[9]
MULTIVARIATE INSTRUMENT STANDARDIZATION [J].
WANG, YD ;
VELTKAMP, DJ ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1991, 63 (23) :2750-2756
[10]
IMPROVEMENT OF MULTIVARIATE CALIBRATION THROUGH INSTRUMENT STANDARDIZATION [J].
WANG, YD ;
LYSAGHT, MJ ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1992, 64 (05) :562-564