Thin-layer chromatography - matrix-assisted laser desorption ionisation - time-of-flight mass spectrometry using particle suspension matrices

被引:59
作者
Crecelius, A
Clench, MR
Richards, DS
Parr, V
机构
[1] Sheffield Hallam Univ, Sch Sci & Math, Sheffield S1 1WB, S Yorkshire, England
[2] Pfizer Global R&D, Sandwich, Kent, England
[3] SAI Ltd, Manchester, Lancs, England
关键词
particle suspension matrix; mass spectrometry; inorganic matrix; matrix-assisted laser desorption ionisation; chlortetracycline; tetracycline;
D O I
10.1016/S0021-9673(02)00391-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Particle suspension matrices have been successfully utilized for the analysis of tetracycline antibiotics by thin-layer chromatography-matrix-assisted laser desorption ionisation-time-of-flight mass spectrometry (TLC-MALDI-TOF-MS). Particles of different materials and sizes have been investigated (Co-UFP, TiN, TiO2, Graphite and Silicon) by applying particle suspensions to eluted TLC plates. Mass spectra and mass chromatograms have been recorded directly from the TLC plates. Strong cationization by sodium and potassium was obtained in the positive ion mode. with [M+Na-NH3](+) ions being the predominant signals. The TLC-MALDI mass spectra recorded from graphite suspensions showed the lowest background noise and the highest peak intensities from the range of suspension matrices studied. The mass accuracy from graphite films was improved by adding the peptide Phe-Phe to the graphite suspensions. This allowed internal recalibration of the TLC-MALDl mass spectra acquired during a run. One major potential advantage of TLC-MALDI-TOF-MS has been demonstrated in the analysis of chlortetracycline and tetracycline in a mixture of oxytetracycline. chlortetracycline, tetracycline and minocycline. Examination of the TLC plate prior to MALDI analysis showed only an unresolved spot for chlortetracycline and tetracycline. However by investigation of the MALDI mass spectra and plotting of single ion chromatograms separate peaks for chlortetracycline and tetracycline could be obtained. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:249 / 260
页数:12
相关论文
共 31 条
[1]  
Busch KL, 1999, SPECTROSCOPY, V14, P14
[2]  
BUSCH KL, 1996, HDB THIN LAYER CHROM, P241
[3]  
Chen YC, 1999, RAPID COMMUN MASS SP, V13, P821, DOI 10.1002/(SICI)1097-0231(19990515)13:9<821::AID-RCM573>3.0.CO
[4]  
2-T
[5]   Thin-layer chromatography mass spectrometry using activated carbon, surface-assisted laser desorption/ionization [J].
Chen, YC ;
Shiea, J ;
Sunner, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (01) :77-86
[6]  
Crecelius A, 2000, JPC-J PLANAR CHROMAT, V13, P76
[7]   Desorption-ionization mass spectrometry using deposited nanostructured silicon films [J].
Cuiffi, JD ;
Hayes, DJ ;
Fonash, SJ ;
Brown, KN ;
Jones, AD .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1292-1295
[8]  
Dale Michael, 1997, Rapid Communications in Mass Spectrometry, V11, P136, DOI 10.1002/(SICI)1097-0231(19970115)11:1<136::AID-RCM811>3.0.CO
[9]  
2-#
[10]   Graphite/liquid mixed matrices for laser desorption/ionization mass spectrometry [J].
Dale, MJ ;
Knochenmuss, R ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3321-3329