Determination of bismuth using on-line preconcentration by trapping on resistively heated W coil and hydride generation atomic absorption spectrometry

被引:51
作者
Cankur, O
Ertas, N
Ataman, OY [1 ]
机构
[1] Middle E Tech Univ, Dept Chem, TR-06531 Ankara, Turkey
[2] Gazi Univ, Dept Analyt Chem, Fac Pharm, TR-06330 Ankara, Turkey
关键词
D O I
10.1039/b201365g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel analytical system was developed to trap and preconcentrate bismuth from the vapour phase stream. Bismuthine formed by sodium tetrahydroborate reduction was trapped on a tungsten coil previously heated to 270 degreesC. The analyte species were re-volatilised by increasing the coil temperature to 1200 degreesC and then transported to an externally heated silica T-tube by using a mixture of argon and hydrogen as the carrier gas. The base width of the transient signal was less than 0.5 s. The reproducibility of the analytical signal was influenced by the rate of heating of the tungsten coil at the releasing stage. The precision of the analytical system was found to be 5.8% RSD (n = 13) for 0.010 ng ml(-1) Bi when peak height was used. Due to sharp signals, peak area readings gave higher RSD values but they could be used for quantitation. The relationship between the analytical signal and the sample volume was found to be linear between 0.5 ml and 60 ml when using 0.100 ng ml(-1) Bi. When the sample volume was increased to 25 ml, the blank values became significant. The calibration plot for an 18 ml sampling volume was linear between 0.030 and 0.500 ng ml(-1) Bi. A limit of detection of 0.0027 ng ml(-1) (3s) was obtained with 18 ml of sample volume. The concentration limit of detection achieved was comparable with or better than those obtained by techniques such as ICP-MS and HG-ETAAS. When the distance between the trap and atomiser was increased to 200 cm, a 72% and 24% decrease was observed in the peak height and peak area, respectively. In order to validate the accuracy of the method, two geological standard reference materials and one certified water standard reference material were analysed and the results were found to be in good agreement with the certified values at the 95% confidence level.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 27 条
[1]   On-line coupling of electrochemical preconcentration in tungsten coil electrothermal atomic absorption spectrometry for determination of lead in natural waters [J].
Barbosa, F ;
Krug, FJ ;
Lima, EC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) :1155-1166
[2]  
Barth P, 1997, J ANAL ATOM SPECTROM, V12, P1351
[3]   Determination of bismuth in biological samples using on-line flow-injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rivas, C ;
Rondon, C ;
Carrero, P ;
Gallignani, M .
TALANTA, 1999, 48 (04) :885-893
[4]   APPLICATIONS OF A SLOTTED TUBE ATOM TRAP AND FLAME ATOMIC-ABSORPTION SPECTROMETRY - DETERMINATION OF BISMUTH IN COPPER-BASED ALLOYS WITH AND WITHOUT HYDRIDE GENERATION [J].
BURNS, DT ;
CHIMPALEE, N ;
HARRIOTT, M .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :93-97
[5]   Determination of bismuth in urine and prescription medicines using atomic absorption with an on-line hydride generation system [J].
Cadore, S ;
dos Anjos, AP ;
Baccan, N .
ANALYST, 1998, 123 (08) :1717-1719
[6]   Determination of Hg and Bi by electrothermal vaporization inductively coupled plasma mass spectrometry using vapor generation with in situ preconcentration in a platinum-coated graphite furnace [J].
Chang, CC ;
Jiang, SJ .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :173-180
[7]   THE APPLICATION OF ELECTRODEPOSITION ON A TUNGSTEN WIRE TO FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
CZOBIK, EJ ;
MATOUSEK, JP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (11-1) :741-751
[8]   Investigation of in situ trapping of selenium and arsenic hydrides within a tungsten tube atomiser [J].
Docekal, B ;
Marek, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :831-837
[9]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY TUNGSTEN COIL ATOMIC-ABSORPTION SPECTROMETRY [J].
GINE, MF ;
KRUG, FJ ;
SASS, VA ;
REIS, BF ;
NOBREGA, JA ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :243-245
[10]  