Calibration of the x-ray CCD camera (XIS) for the ASTRO-E in the soft x-ray band

被引:6
作者
Katayama, H [1 ]
Shouho, M [1 ]
Kohmura, T [1 ]
Katayama, K [1 ]
Ohta, M [1 ]
Tsunemi, H [1 ]
Kitamoto, S [1 ]
Hayashida, K [1 ]
Miyata, E [1 ]
Yoshita, K [1 ]
Koyama, K [1 ]
Ricker, G [1 ]
Bautz, MW [1 ]
Foster, R [1 ]
Kissel, S [1 ]
Doty, J [1 ]
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Toyonaka, Osaka 5600043, Japan
来源
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X | 1999年 / 3765卷
关键词
XIS; calibration; response; simulation;
D O I
10.1117/12.366554
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The ASTRO-E X-ray Imaging Spectrometers (XISs) consists of four sets of X-ray CCD camera for the ASTRO-E mission. The XISs have been calibrated at Osaka University: KJ oto University, ISAS and MIT. The calibration experiment. at, Osaka focuses on the soft, X-ray response of the XIS (from 0.25 to 2.2 keV). The calibration of the XIS Flight Model (XIS FM) has been performed since: August 1998. We measured the signal-pulse height, the energy resolution and the quantum efficiency of the XIS as a function of energy of which are essential to construct the response function of the XIS. The detailed shape of the pulse-height-distribution, are also investigated. We also constructed a numerical simulator of the XIS, which tracks the physical processes in the CCD so as to reproduce the measured data. With a help of this simulator, we propose a model for the pulse-height-distribution of the XIS for single energy incident X-rays. The model consists of four components; two Gaussians, a constant, plus a triangle-shape component.
引用
收藏
页码:721 / 728
页数:8
相关论文
共 16 条
[1]  
BAUTZ MW, 1998, CALIBRATION REPORT A
[2]   Soft-x-ray CCD imagers for AXAF [J].
Burke, BE ;
Gregory, JA ;
Bautz, MW ;
Prigozhin, GY ;
Kissel, SE ;
Kosicki, BB ;
Loomis, AH ;
Young, DJ .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1997, 44 (10) :1633-1642
[3]   THE X-RAY-ENERGY RESPONSE OF SILICON .A. THEORY [J].
FRASER, GW ;
ABBEY, AF ;
HOLLAND, A ;
MCCARTHY, K ;
OWENS, A ;
WELLS, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :368-378
[4]  
Gendreau K.C., 1995, THESIS MIT
[5]   Continuum x-ray source as a calibration system for charge coupled devices [J].
Hashimotodani, K ;
Toneri, T ;
Kitamoto, S ;
Tsunemi, H ;
Hayashida, K ;
Miyata, E ;
Katayama, K ;
Kohomura, T ;
Asakura, R ;
Koyama, K ;
Yamamoto, K ;
Miyaguchi, K ;
Suzuki, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) :392-395
[6]   Soft X-ray response of the proto-type CCD camera (XIS) for Astro-E [J].
Hayashida, K ;
Kitamoto, S ;
Miyata, E ;
Tsunemi, H ;
Hashimotodani, K ;
Katayama, K ;
Kohmura, T ;
Asakura, R ;
Yoshita, K ;
Katayama, H ;
Shouho, M ;
Koyoma, K ;
Tsuru, TG ;
Awaki, H ;
Dotani, T ;
Ozaki, M ;
Ricker, G ;
Doty, J ;
Bautz, M ;
Kissel, S ;
Foster, R .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 :278-290
[7]   VARIABLE LINE-SPACE GRATINGS - NEW DESIGNS FOR USE IN GRAZING-INCIDENCE SPECTROMETERS [J].
HETTRICK, MC ;
BOWYER, S .
APPLIED OPTICS, 1983, 22 (24) :3921-3924
[8]   ABERRATIONS OF VARIED LINE-SPACE GRAZING-INCIDENCE GRATINGS IN CONVERGING LIGHT-BEAMS [J].
HETTRICK, MC .
APPLIED OPTICS, 1984, 23 (18) :3221-3235
[9]  
KATAYAMA K, 1999, THESIS GRADUATE SCH
[10]  
MCCARTH KJ, 1955, NIMA, V362, P538