Noninvasive glucose monitoring - Comprehensive clinical results

被引:196
作者
Tamada, JA
Garg, S
Jovanovic, L
Pitzer, KR
Fermi, S
Potts, RO
机构
[1] Cygnus Inc, Redwood City, CA 94063 USA
[2] Univ Colorado, Hlth Sci Ctr, Barbara Davis Ctr Childhood Diabet, Denver, CO 80262 USA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 1999年 / 282卷 / 19期
关键词
D O I
10.1001/jama.282.19.1839
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context Intensive diabetes management using frequent blood glucose measurements to guide therapy has been shown to significantly improve short- and long-term outcomes. Development of a device that makes possible frequent, automatic, painless, and accurate measurements of glucose would facilitate intensive management. Objective To determine the accuracy of the GlucoWatch automatic glucose biographer (Cygnus Inc) compared with that of serial blood glucose measurements. Design Multicenter comparative study of the GlucoWatch biographer and the HemoCue blood glucose analyzer (Aktiebolaget Lee) performed between August 29 and October 17, 1998, Participants wore up to 2 biographers during the 15-hour study session and performed 2 fingersticks per hour for comparative blood glucose measurements, The biographers were calibrated with a single HemoCue measurement after a 3-hour warm-up period, Diet and insulin were manipulated to produce a broad glycemic range during the study. Setting Controlled clinical environment at 2 diabetes centers and 3 contract research organizations in the United States. Participants A total of 92 subjects (mean [SD] age, 42.1 [15.1] years; 59.8% women) with type 1 or 2 diabetes requiring treatment with insulin. Main Outcome Measures Mean error, mean absolute error, correlation, slope, and intercept using Deming regression, and clinical significance of differences between biographer readings and blood glucose measurements using the Clarke error grid. Results Results showed close tracking of blood glucose over a range of 2.2 to 22.2 mmol/L (40-400 mg/dL) for up to 12 hours using a single point calibration. The biographer readings lagged behind serial blood glucose values by a mean of 18 minutes. An analysis of 2167 data pairs shows a linear relationship (r = 0.88; slope = 1.03; intercept = -0.33 mmol/L [-6 mg/dL]) between biographer readings and serial glucose measurements. The mean absolute error between the 2 measurements was 15.6% (mean error [SD], -0.07 [1.82] mmol/L [-1 (33) mg/dL]), and 96.8% of the data fell in the therapeutically relevant regions of the error grid analysis. Conclusion These results demonstrate close agreement between GlucoWatch biographer readings and blood glucose measurements using repeated fingerstick blood samples. The automatic, frequent, and noninvasive measurements obtained with the biographer provides more information about glucose levels than the current standard of care.
引用
收藏
页码:1839 / 1844
页数:6
相关论文
共 20 条
[1]   Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions [J].
Bolinder, J ;
HagstromToft, E ;
Ungerstedt, U ;
Arner, P .
DIABETES CARE, 1997, 20 (01) :64-70
[2]   Validation of home blood glucose meters with respect to clinical and analytical approaches [J].
Brunner, GA ;
Ellmerer, M ;
Sendlhofer, G ;
Wutte, A ;
Trajanoski, Z ;
Schaupp, L ;
Quehenberger, F ;
Wach, P ;
Krejs, GJ ;
Pieber, TR .
DIABETES CARE, 1998, 21 (04) :585-590
[3]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[4]  
Diabetes Control and Complications Trial Research Group, 1993, NEW ENGL J MED, V329, P997
[5]  
Draize JH, 1944, J PHARMACOL EXP THER, V82, P377
[6]   NONINVASIVE SAMPLING OF BIOLOGICAL-FLUIDS BY IONTOPHORESIS [J].
GLIKFELD, P ;
HINZ, RS ;
GUY, RH .
PHARMACEUTICAL RESEARCH, 1989, 6 (11) :988-990
[7]   Application of the Mixtures of Experts algorithm for signal processing in a noninvasive glucose monitoring system [J].
Kurnik, RT ;
Oliver, JJ ;
Waterhouse, SR ;
Dunn, T ;
Jayalakshmi, Y ;
Lesho, M ;
Lopatin, M ;
Tamada, J ;
Wei, C ;
Potts, RO .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 60 (01) :19-26
[8]   Design and simulation of a reverse iontophoretic glucose monitoring device [J].
Kurnik, RT ;
Berner, B ;
Tamada, J ;
Potts, RO .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (12) :4119-4125
[9]  
KURNIK RT, 1997, Patent No. 24059
[10]   ON LINE CONTINUOUS MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE IN MEN BY COMBINING PORTABLE GLUCOSENSOR WITH MICRODIALYSIS [J].
MEYERHOFF, C ;
BISCHOF, F ;
STERNBERG, F ;
ZIER, H ;
PFEIFFER, EF .
DIABETOLOGIA, 1992, 35 (11) :1087-1092