Competitive immunoassay method for 5-methyl-2′-deoxycytidine

被引:5
作者
Darwish, I
Emara, S
Askal, H [1 ]
El-Rabbat, N
Omura, K
Hirose, K
Akizawa, T
Yoshioka, M
机构
[1] Assiut Univ, Fac Pharm, Assiut, Egypt
[2] Suez Canal Univ, Fac Pharm, Ismailia, Egypt
[3] Setsunan Univ, Fac Pharmaceut Sci, Osaka 57301, Japan
关键词
5-methyl-2 '-deoxycytidine; biological leukemic marker; monoclonal antibody; competitive immunoassay;
D O I
10.1016/S0003-2670(00)00801-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper describes the preparation of monoclonal antibodies against 5-methyl-2'-deoxycytidine (5MedCyd) and its utility in the development of a competitive immunoassay system for 5MedCyd. The hybridoma was constructed by fusion of the spleen cells removed from mouse immunized with 3'-succinyl-2'-deoxycytidine keyhole-limpet hemocyanin conjugate with SP2/0-Ag14 myeloma cells. Three high titer clones that secreted anti 5MedCyd antibodies were selected. The antibodies from the three clones recognize 5MedCyd; however, small cross reactivity was observed with 5-methylcytidine and 5-methylcytosine, which possess 5-methylcytosine moiety in their structure. The clone that showed the lowest cross reactivity with these compounds was designated as 8C-4. 8C-4 antibody, which had very slight cross reactivity with the other adenosine and guanosine analogues tested in our investigation particularly the methylated ones. This monoclonal antibody was used for establishment of an immunoassay method for 5MedCyd. In this method, 8C-4 antibody was allowed to react with the free 5MedCyd in a standard solution or a urine sample in competition with 3'-succinyl-2'-deoxycytidine bovine serum albumin conjugate immobilized on microtiter plate wells, Bound antibody was quantified with alkaline phosphatase-labeled goat anti-mouse secondary antibody and p-nitrophenylphosphate substrate solution. A linear relationship with good correlation coefficient was obtained over the range 1-40 mu M. The specificity, reproducibility and accuracy of the proposed method was proved. There is a good correlation between the results obtained by this method and by liquid chromatography over the entire linear range. By this system, evaluation of the urinary 5MedCyd level as a biological marker for leukemic patients will be possible. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 24 条
[1]  
AGWARD R, 1982, J CHROMATOGR-BIOMED, V231, P418
[2]  
ALAIN N, 1994, NUCLEIC ACIDS RES, V22, P5508
[3]   EXPERIENCE WITH A SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE ANALYSIS OF PURINE AND PYRIMIDINE NUCLEOSIDES AND BASES IN BIOLOGICAL-FLUIDS [J].
BENNETT, MJ ;
CARPENTER, KH .
ANNALS OF CLINICAL BIOCHEMISTRY, 1984, 21 (MAR) :131-136
[4]  
CORY JG, 1992, TXB BIOCH CLIN CORRE
[5]  
Engvall E, 1980, Methods Enzymol, V70, P419
[6]   QUANTITATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF NUCLEOSIDES IN BIOLOGICAL-MATERIALS [J].
GEHRKE, CW ;
KUO, KC ;
DAVIS, GE ;
SUITS, RD ;
WAALKES, TP ;
BOREK, E .
JOURNAL OF CHROMATOGRAPHY, 1978, 150 (02) :455-476
[7]  
GEHRKE CW, 1983, RECENT RES CANCER, V84, P344
[8]  
GEHRKE CW, 1979, CANCER RES, V39, P1150
[9]   QUANTITATIVE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF MAJOR AND MODIFIED NUCLEOSIDES IN DNA [J].
GEHRKE, CW ;
MCCUNE, RA ;
GAMASOSA, MA ;
EHRLICH, M ;
KUO, KC .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (01) :199-219
[10]  
IBRAHIM D, 1998, ANAL CHIM ACTA, V365, P121