13C-octanoic acid breath test for gastric emptying measurement

被引:65
作者
Delbende, B [1 ]
Perri, F [1 ]
Couturier, O [1 ]
Leodolter, A [1 ]
Mauger, P [1 ]
Bridgi, B [1 ]
Bizais, Y [1 ]
des Varannes, SB [1 ]
Andriulli, A [1 ]
Galmiche, JP [1 ]
机构
[1] CHU Nantes, Hotel Dieu, Dept Gastroenterol & Hepatol, F-44035 Nantes, France
关键词
breath test; gastric emptying; octanoic acid; scintigraphy;
D O I
10.1097/00042737-200012010-00016
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives The purpose of this multicentre study was to assess the accuracy and reproducibility of the C-13-octanoic acid breath test compared to scintigraphy for measurement of gastric emptying. Methods Sixty-nine healthy subjects (40 men, 29 women; mean age 30 years, range 21-61) were studied at least once by using the C-13-octanoic breath test, In 34 healthy subjects, gastric emptying was simultaneously measured by gastric scintigraphy, and the C-13-octanoic breath test was then repeated in 18 of these cases, Fifty-four patients (30 men, 24 women; mean age 46 years, range 13-74) with dyspeptic or reflux symptoms were studied according to the same procedure. Results The correlation between breath test and scintigraphic values was highly significant(r = 0.744, P < 0.001), The concordance of results of scintigraphy and breath test (normal versus abnormal) and the reproducibility (Bland and Altman method) of the breath test were good (CVinter = 24%, CVintra = 15%). As compared to scintigraphy, breath test detected an abnormal gastric emptying with 67% sensitivity and 80% specificity (ROC analysis). Conclusion These results confirm the value of breath test as an accurate measurement of gastric emptying, Its excellent reproducibility makes it a method of choice for pharmacological studies. However, at least when scintigraphy is considered the gold standard, breath test sensitivity may be insufficient for the detection of gastroparesis in an individual patient. (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 21 条
[1]   MEDIUM-CHAIN TRIGLYCERIDES - AN UPDATE [J].
BACH, AC ;
BABAYAN, VK .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1982, 36 (05) :950-962
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   [C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
GASTROENTEROLOGY, 1997, 112 (04) :1155-1162
[4]  
Choi MG, 1997, GASTROENTEROLOGY, V112, pA712
[5]   INHIBITION OF STEADY-STATE INTESTINAL ABSORPTION OF LONG-CHAIN TRIGLYCERIDE BY MEDIUM-CHAIN TRIGLYCERIDE IN UNANESTHETIZED RAT [J].
CLARK, SB ;
HOLT, PR .
JOURNAL OF CLINICAL INVESTIGATION, 1969, 48 (12) :2235-+
[6]  
ELASHOFF JD, 1982, GASTROENTEROLOGY, V83, P1306
[7]   MEASUREMENT OF GASTRIC-EMPTYING RATE OF SOLIDS BY MEANS OF A CARBON-LABELED OCTANOIC-ACID BREATH TEST [J].
GHOOS, YF ;
MAES, BD ;
GEYPENS, BJ ;
MYS, G ;
HIELE, MI ;
RUTGEERTS, PJ ;
VANTRAPPEN, G .
GASTROENTEROLOGY, 1993, 104 (06) :1640-1647
[8]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66
[9]   GLUCOSE NATURALLY LABELED WITH C-13 - USE FOR METABOLIC STUDIES IN MAN [J].
LACROIX, M ;
MOSORA, F ;
PONTUS, M ;
LEFEBVRE, P ;
LUYCKX, A ;
LOPEZHAB.G .
SCIENCE, 1973, 181 (4098) :444-446
[10]   INTERSUBJECT AND INTRASUBJECT VARIABILITY OF SOLID AND LIQUID GASTRIC-EMPTYING PARAMETERS - A SCINTIGRAPHIC STUDY IN HEALTHY-SUBJECTS AND DIABETIC-PATIENTS [J].
LARTIGUE, S ;
BIZAIS, Y ;
DESVARANNES, SB ;
MURAT, A ;
POULIQUEN, B ;
GALMICHE, JP .
DIGESTIVE DISEASES AND SCIENCES, 1994, 39 (01) :109-115