Specific determination of As(V) by an acid phosphatase-polyphenol oxidase biosensor

被引:74
作者
Cosnier, Serge [1 ]
Mousty, Christine
Cui, Xiaoqiang
Yang, Xiurong
Dong, Shaojun
机构
[1] Univ Grenoble 1, Lab Electrochim Organ & Photochim Redox, UMR 5630, ICMG,FR 2607,CNRS, Grenoble, France
[2] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
关键词
D O I
10.1021/ac060064d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An original amperometric biosensor based on the simultaneous entrapment of acid phosphatase (AcP) and polyphenol oxidase (PPO) into anionic clays (layered double hydroxides) was developed for the specific detection of As(V). The functioning principle of the bienzyme electrode consisted of the successive hydrolysis of phenyl phosphate into phenol by AcP, followed by the oxidation of phenol into o-quinone by PPO. The phenyl phosphate concentration was, thus, monitored by potentiostating the biosensor at -0.2 V vs Ag/AgCl to detect amperometrically the generated quinone. The detection of As(V) was based on its inhibitory effect on AcP activity toward the hydrolysis of phenyl phosphate into phenol. The As(V) can be specifically determined in pH 6.0 acetate buffer without any interferences of As(III) or phosphate, the detection limit being 2 nM or 0.15 ppb after an incubation step for 20 min.
引用
收藏
页码:4985 / 4989
页数:5
相关论文
共 32 条
  • [1] Electroanalytical determination of acid phosphatase activity by monitoring p-nitrophenol
    Calvo-Marzal, P
    Rosatto, SS
    Granjeiro, PA
    Aoyama, H
    Kubota, LT
    [J]. ANALYTICA CHIMICA ACTA, 2001, 441 (02) : 207 - 214
  • [2] Analysis and speciation of traces of arsenic in environmental food and industrial samples by voltammetry: a review
    Cavicchioli, A
    La-Scalea, MA
    Gutz, IGR
    [J]. ELECTROANALYSIS, 2004, 16 (09) : 697 - 711
  • [3] Stability and catalytic kinetics of acid phosphatase immobilized on composite beads of chitosan and activated clay
    Chang, MY
    Juang, RS
    [J]. PROCESS BIOCHEMISTRY, 2004, 39 (09) : 1087 - 1091
  • [4] Determination of arsenic compounds in beverages by high-performance liquid chromatography-inductively coupled plasma mass spectrometry
    Coelho, NMM
    Coelho, LM
    de Lima, ES
    Pastor, A
    de la Guardia, M
    [J]. TALANTA, 2005, 66 (04) : 818 - 822
  • [5] An bienzyme electrode (alkaline phosphatase polyphenol oxidase) for the amperometric determination of phosphate
    Cosnier, S
    Gondran, C
    Watelet, JC
    De Giovani, W
    Furriel, RPM
    Leone, FA
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3952 - 3956
  • [6] A NEW STRATEGY FOR THE CONSTRUCTION OF A TYROSINASE-BASED AMPEROMETRIC PHENOL AND O-DIPHENOL SENSOR
    COSNIER, S
    INNOCENT, C
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1993, 31 (02): : 147 - 160
  • [7] Photometric measurement of trace As(III) and As(V) in drinking water
    Dasgupta, PK
    Huang, HL
    Zhang, GF
    Cobb, GP
    [J]. TALANTA, 2002, 58 (01) : 153 - 164
  • [8] Urea biosensors based on immobilization of urease into two oppositely charged clays (Laponite and Zn-Al layered double hydroxides)
    de Melo, JV
    Cosnier, S
    Mousty, C
    Martelet, C
    Jaffrezic-Renault, N
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4037 - 4043
  • [9] de Roy A., 1991, Expanded Clays and Other Microporous Solids, P108, DOI [DOI 10.1007/978-1-4684-8866-1_7, 10.1007/978-1-4684-8866-1_7]
  • [10] Forano C, 2006, DEV CLAY SCI, V1, P1021, DOI 10.1016/S1572-4352(05)01039-1