Optimization of solid-phase microextraction procedures for the determination of tricyclic antidepressants and anticonvulsants in plasma samples by liquid chromatography

被引:54
作者
Cantu, Marcelo Delmar
Toso, Daniel Rodrigo
Lacerda, Cristina Alves
Lancas, Fernando Mauro
Carrilho, Emanuel
Queiroz, Maria Eugenia Costa
机构
[1] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Quim, BR-14040901 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
关键词
solid-phase microextraction; tricyclic antidepressants; anticonvulsants; factorial design; plasma samples; bioanalytical methods;
D O I
10.1007/s00216-006-0629-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simple, sensitive, and reproducible off-line solid-phase microextraction and liquid chromatography (SPME/LC) methods are described for the determination of seven anticonvulsants and tricyclic antidepressants in human plasma. Factorial design and simplex methodology were applied in the optimization of the SPME procedure for tricyclic antidepressants analyses. Important factors in the SPME efficiency are discussed, such as the fiber coatings (both lab-made and commercial), extraction time, pH, ionic strength, influence of plasma proteins, and desorption conditions. The development of the lab-made fiber coatings, namely, octadecylsilane, aminosilane, and polyurethane, are further described and applied to anticonvulsants analyses. The investigated plasmatic range for the evaluated anticonvulsants, using CW-TPR fiber, were the following: phenylethylmalonamide (3.00-40.0 mu g mL(-1)), phenobarbital (5.00-40.0 mu g mL(-1)), primidone (3.00-40.0 mu g mL(-1)), carbamazepine and carbamazepine-epoxide (2.00-24.0 mu g mL(-1)), phenytoin (2.00-40.0 mu g mL(-1)), and lamotrigine (0.50-12.0 mu g mL(-1)). The antidepressants' linear plasmatic concentration ranged from 75.0 to 500 ng mL(-1) for imipramine, amitriptyline, and desipramine, and from 50.0 to 500 ng mL(-1) for nortriptyline, being in all cases, the limit of quantification represented by the lowest value. The precision (interassays) for all investigated drugs in plasma sample spiked with different concentrations of each analyte and submitted to the described procedures were lower than 15%. The off-line SPME/LC methodologies developed allow anticonvulsants and antidepressants analyses from therapeutic to toxic levels for therapeutic drug monitoring.
引用
收藏
页码:256 / 263
页数:8
相关论文
共 40 条
[11]   Simultaneous determination of seven tricyclic antidepressant drugs in human plasma by direct-injection HPLC-APCI-MS-MS with an ion trap detector [J].
Kollroser, M ;
Schober, C .
THERAPEUTIC DRUG MONITORING, 2002, 24 (04) :537-544
[12]   Solid-phase microextraction for herbicide determination in environmental samples [J].
Krutz, LJ ;
Senseman, SA ;
Sciumbato, AS .
JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) :103-121
[13]  
Kumazawa T, 2000, J MASS SPECTROM, V35, P1091
[14]  
Lanças FM, 2004, LC GC N AM, V22, P970
[15]   Routine therapeutic drug monitoring in patients treated with 10-360 mg/day citalopram [J].
Le Bloc'h, Y ;
Woggon, B ;
Weissenrieder, H ;
Brawand-Amey, M ;
Spagnoli, J ;
Eap, CB ;
Baumann, P .
THERAPEUTIC DRUG MONITORING, 2003, 25 (05) :600-608
[16]   Effect of the doping medium on blends of polyurethane and polyaniline [J].
Malmonge, JA ;
Campoli, CS ;
Malmonge, LF ;
Kanda, DHF ;
Mattoso, LHC ;
Chierice, GO .
SYNTHETIC METALS, 2001, 119 (1-3) :87-88
[17]   Liquid chromatographic determination of oxcarbazepine and its metabolites in plasma of epileptic patients after solid-phase extraction [J].
Mandrioli, R ;
Ghedini, N ;
Albani, F ;
Kenndler, E ;
Raggi, MA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01) :253-263
[18]  
Miller J. C., 1993, STAT ANAL CHEM
[19]  
Müller MJ, 2003, PHARMACOPSYCHIATRY, V36, P98
[20]   Simple and simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood by gas chromatography-mass spectrometry after headspace-solid phase microextraction and derivatization [J].
Namera, A ;
Yashiki, M ;
Liu, JT ;
Okajima, K ;
Hara, K ;
Imamura, T ;
Kojima, T .
FORENSIC SCIENCE INTERNATIONAL, 2000, 109 (03) :215-223