Applications of chlorophyll fluorescence for stock quality assessment with different types of fluorometers

被引:37
作者
Binder, WD [1 ]
Fielder, P [1 ]
Mohammed, GH [1 ]
LHirondelle, SJ [1 ]
机构
[1] ONTARIO FOREST RES INST, SAULT ST MARIE, ON P6A 5N5, CANADA
关键词
chlorophyll fluorescence; damage; drought; fluorometer; freezing; heating; jack pine; Sitka spruce; stress; water potential; white spruce;
D O I
10.1023/A:1006513720073
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
We demonstrate some stress detection and stock quality applications of fluorescence to conifer seedlings using two types of fluorometers: an integrating fluorometer (TF) for laboratory use, and two field-portable pulse-modulated instruments, the EARS-PPM (EARS) and PAM-2000 (PAM). Freezing tests showed that as temperature decreased, the IF and EARS detected decreased fluorescence in white spruce (Picea glauca [Moench.] Voss) seedlings (r(2) >0.90 with visible injury). Fv/F-m from the IF was highly correlated with quantum yield (phi p) from the EARS (r >0.94). The relationship between phi p and visible injury in white spruce was strongest when phi p was measured at low light levels. Freezing-stressed Sitka spruce (Picea sitchensis [Bong.] Carr.) seedlings also showed decreased phi p. Values of phi(p) in the dark were about 20% higher than in the light (400 mu mol m(-2) s(-1) PPFD, photosynthetic photon flux density); but the two phi ps were highly correlated (r(2)=0.99). Heating Sitka spruce seedlings showed that phi p decreased linearly as duration at 40 degrees C increased. Although there was some recovery in phi p, after 5 days, it was a good indicator of subsequent growth. Desiccation tests showed that the PAM and IF both detected water stress in jack pine (Pinus banksiana Lamb.) seedlings but the values for F-v/F-m differed. Moderate stress was detected by the PAM as higher q(N) and lower phi p, and by the IF as delayed Ft(M2), For severe stress, the PAM detected lower F-v/F-m, q(N), q(p), and phi p, and F-M2 disappeared from IF curves. Gross photosynthesis (Gp), measured by the EARS, can be used as be a quick estimator of net photosynthesis (P >0.90), but its use as an estimator of seedling quality requires further study.
引用
收藏
页码:63 / 89
页数:27
相关论文
共 34 条
[31]   ASSESSMENT OF PHOTOSYNTHETIC ACTIVITY OF NURSERY-GROWN PICEA-GLAUCA SEEDLINGS USING AN INTEGRATING FLUOROMETER TO MONITOR VARIABLE CHLOROPHYLL FLUORESCENCE [J].
VIDAVER, W ;
BINDER, W ;
BROOKE, RC ;
LISTER, GR ;
TOIVONEN, PMA .
CANADIAN JOURNAL OF FOREST RESEARCH-REVUE CANADIENNE DE RECHERCHE FORESTIERE, 1989, 19 (11) :1478-1482
[32]  
VIDAVER WE, 1991, MANUAL USE VARIABLE
[33]  
1993, PORTABLE FLUOROMETER
[34]  
1993, EARS PPM MANUAL INGE