Field Performance of Seven Passive Sampling Devices for Monitoring of Hydrophobic Substances

被引:113
作者
Allan, Ian J. [1 ,2 ]
Booij, Kees
Paschke, Albrecht [3 ,4 ]
Vrana, Branislav [5 ]
Mills, Graham A. [6 ]
Greenwood, Richard [2 ]
机构
[1] Norwegian Inst Water Res, NO-0349 Oslo, Norway
[2] Univ Portsmouth, Sch Biol Sci, Portsmouth PO1 2DY, Hants, England
[3] Royal Netherlands Inst Sea Res, NL-1790 AB Texel, Netherlands
[4] UFZ Helmholtz Ctr Environm Res, Dept Ecol Chem, D-04318 Leipzig, Germany
[5] Water Res Inst, Natl Water Ref Lab Slovakia, Bratislava 81249, Slovakia
[6] Univ Portsmouth, Sch Pharm & Biomed Sci, Portsmouth PO1 2DT, Hants, England
关键词
SEMIPERMEABLE-MEMBRANE DEVICES; LOW-DENSITY POLYETHYLENE; PARTITION-COEFFICIENTS; ORGANIC POLLUTANTS; UPTAKE KINETICS; WATER; CALIBRATION; CONTAMINANTS; SEDIMENTS; PHASE;
D O I
10.1021/es900608w
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of seven passive sampling devices for the monitoring of dissolved concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBS), hexachlorobenzene, and p,p'-DDE was evaluated through simultaneous field exposures of 7-28 days in the River Meuse (The Netherlands). Data from the Chemcatcher, low density polyethylene membranes, two versions of the membrane-enclosed sorptive coating (MESCO) sampler, silicone rods, silicone strips and semipermeable membrane devices (SPMD) was assessed through rate of dissipation of performance reference compounds (PRCs), mass of analyte absorbed by the samplers and time-weighted average concentration (C(TWA)) data. Consistent PRC data throughout the range of samplers tested here confirmed the transition from membrane- to boundary layer-controlled exchange at log K(OW) 4.5-5.0. The comparison of sampler surface area-normalized masses absorbed for analytes under boundary layer-control showed some variability between samplers that can be attributed to the conformation and deployment of the various samplers and to the uncertainty associated with the analysis conducted in different laboratories. Despite different modes of calculation, relatively consistent C(TWA) were obtained for the different samplers. The observed variability is likely to be due to the uncertainty of sampler-water partition coefficients and the extrapolation of analyte uptake rates at the high log K(OW) range (under boundary layer-controlled exchange) from a narrow PRC data range, and these issues require further work. Finally, the usefulness of passive sampler-generated contaminant concentrations is demonstrated through the comparison with institutional monitoring and with European Water Framework Directive Environmental Duality Standards (EQS).
引用
收藏
页码:5383 / 5390
页数:8
相关论文
共 27 条
[1]   Strategic monitoring for the European Water Framework Directive [J].
Allan, Ian J. ;
Mills, Graham A. ;
Vrana, Branislav ;
Knutsson, Jesper ;
Holmberg, Arne ;
Guigues, Nathalie ;
Laschi, Serena ;
Fouillac, Anne-Marie ;
Greenwood, Richard .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :704-715
[2]   A "toolbox" for biological and chemical monitoring requirements for the European Union's Water Framework Directive [J].
Allan, IJ ;
Vrana, B ;
Greenwood, R ;
Mills, GA ;
Roig, B ;
Gonzalez, C .
TALANTA, 2006, 69 (02) :302-322
[3]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245
[4]   Temperature-dependent uptake rates of nonpolar organic compounds by semipermeable membrane devices and low-density polyethylene membranes [J].
Booij, K ;
Hofmans, HE ;
Fischer, CV ;
Van Weerlee, EM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (02) :361-366
[5]   Dissolved PCBs, PAHs, and HCB in pore waters and overlying waters of contaminated harbor sediments [J].
Booij, K ;
Hoedemaker, JR ;
Bakker, JF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (18) :4213-4220
[6]   Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers [J].
Booij, K ;
Smedes, F ;
van Weerlee, EM .
CHEMOSPHERE, 2002, 46 (08) :1157-1161
[7]   Little effect of excessive biofouling on the uptake of organic contaminants by semipermeable membrane devices [J].
Booij, Kees ;
van Bommel, Ronald ;
Mets, Anchelique ;
Dekker, Rob .
CHEMOSPHERE, 2006, 65 (11) :2485-2492
[8]   Estimating dissolved organic carbon partition coefficients for nonionic organic chemicals [J].
Burkhard, LP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (22) :4663-4668
[9]  
Huckins J.N., 2006, Monitors of Organic Chemicals in the Environment: Semipermeable Membrane Devices
[10]   Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices [J].
Huckins, JN ;
Petty, JD ;
Lebo, JA ;
Almeida, FV ;
Booij, K ;
Alvarez, DA ;
Clark, RC ;
Mogensen, BB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) :85-91