Monitoring body-core temperature from the trachea: Comparison between pulmonary artery, tympanic, esophageal, and rectal temperatures

被引:19
作者
Hayes, JK
Collette, DJ
Peters, JL
Smith, KW
机构
[1] Department of Ancsthesiology, University ot Utah, College of Medicine, Salt Lake City, UT 84132
[2] University of Utah, College of Medicine, Department of Anesthesiology, Salt Lake City
来源
JOURNAL OF CLINICAL MONITORING | 1996年 / 12卷 / 03期
关键词
endotracheal tube; humidity; temperature monitoring; tracheal; core; pulmonary artery; esophageal; tympanic; rectal;
D O I
10.1007/BF00857648
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Introduction. We designed an endotracheal tube (ETT) for acquiring body-core temperature from the trachea. This ETT had two temperature sensors, one attached to the inside surface of the cuff, the other mounted on the ETT shaft underneath the cuff. The ETT was evaluated in vitro and in dogs to determine: 1) optimal position of temperature sensors and 2) the responsiveness, accuracy and resistance to ventilatory artifacts. Methods. In vitro. An artificial trachea assessed the response-time and accuracy of ETT temperature sensors to abrupt: temperature changes and ventilatory flow-rates. In viva. Body temperature in 5 dogs was lowered to approximately 26 degrees C then elevated toward 39 degrees C using a heat exchanger during carotid-jugular bypass. ETT temperature measurements were compared simultaneously with those from the artificial trachea (in vitro) or from the pulmonary artery, tympanic cavity, esophagus, and rectum of dogs using dry and humidified gas. Results. Cuff temperature sensor responded quickly and accurately to temperature changes and was less prone than the tube sensor to ventilatory and humidity artifacts. During carotid-jugular bypass, in vivo tube and cuff mean temperatures averaged 1.4 degrees C and 0.36 degrees C lower, respectively, than pulmonary artery temperatures. There were no statistical differences (P > 0.05) between cuff temperatures and those measured from the pulmonary artery, tympanic cavity, esophagus, and rectum. Heating and humidifying the inspiratory gas of dogs with a water-bath humidifer or heat moisture exchanger (HME) had minimal effects on the cuff temperature sensor. An in-line HME increased in vivo tube temperature from baseline values by 1.13 +/- 0.80 degrees C, while cuff temperature increased by 0.21 +/- 0.24 degrees C. Conclusion. The cuff of the ETT is a reliable site for measuring body-core temperature in intubated patients.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 30 条
[11]  
Earp J K, 1992, Am J Crit Care, V1, P43
[12]  
ERICKSON RS, 1993, CRIT CARE MED, V21, P528
[13]   TEMPERATURE CHANGES IN THE BLOOD OF THE PULMONARY ARTERY AND LEFT ATRIUM OF DOGS DURING EXPOSURE TO EXTREME COLD [J].
GOOD, AL ;
SELLERS, AF .
AMERICAN JOURNAL OF PHYSIOLOGY, 1957, 188 (03) :447-450
[14]  
HAYES JK, 1994, J CLIN MONITOR, V10, P15
[15]   URINARY-BLADDER TEMPERATURE MONITORING IN EXTENSIVELY BURNED PATIENTS [J].
IMAIZUMI, H ;
TSUNODA, K ;
ICHIMIYA, N ;
OKAMOTO, T ;
NAMIKI, A .
JOURNAL OF CLINICAL MONITORING, 1993, 9 (02) :99-100
[16]   CORE TEMPERATURE MEASURED IN THE AURICULAR CANAL - COMPARISON BETWEEN 4 DIFFERENT TYMPANIC THERMOMETERS [J].
JAKOBSSON, J ;
NILSSON, A ;
CARLSSON, L .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (08) :819-824
[17]  
KAUFMAN RD, 1987, ANESTH ANALG, V66, P1046
[18]  
KAWANO Y, 1992, ANESTHESIOLOGY, V77, pA563
[19]   A COMPARISON OF ORAL, AXILLARY, RECTAL AND TYMPANIC-MEMBRANE TEMPERATURES OF INTENSIVE-CARE PATIENTS WITH AND WITHOUT AN ORAL ENDOTRACHEAL-TUBE [J].
KONOPAD, E ;
KERR, JR ;
NOSEWORTHY, T ;
GRACE, M .
JOURNAL OF ADVANCED NURSING, 1994, 20 (01) :77-84
[20]   EFFECTS OF VASODILATORS ON RATES OF CHANGE OF NASOPHARYNGEAL TEMPERATURE AND SYSTEMIC VASCULAR-RESISTANCE DURING CARDIOPULMONARY BYPASS IN ANESTHETIZED DOGS [J].
LI, DMF ;
MULLALY, R ;
EWER, P ;
BELL, B ;
EYRES, RL ;
BRAWN, WJ ;
MEE, RBB .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1988, 58 (04) :327-333