Gas chromatographic retention index system for polychlorinated biphenyls: possibilities and limitations

被引:16
作者
Castello, G
Testini, G
机构
[1] Università di Genova, Dipto. di Chim. e Chim. Industriale, 16146 Genova
关键词
retention indices; stationary phases; GC; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(97)00662-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The identification of individual polychlorinated biphenyls (PCBs) congeners would be easier if a proper reference series were available to calculate retention indices when using electron capture detectors, which are insensitive to the n-alkanes. In a previous work, a mixture of PCBs showing a linear dependence of retention on the number of chlorine atoms in both isothermal and programmed temperature analysis was suggested for reference purposes. Retention index values referred to this series, I-PCB, can be calculated and used for identification. In this work a wide collection of columns was tested in order to check the linearity of the proposed reference series. The effect of the initial temperature and heating rate of the programmed runs on the reproducibility of the results was investigated. Retention data of the congeners belonging to the reference series are given together with retention indices of toxic PCB congeners calculated for various columns. The inversion of the elution order or the shift of retention values on columns of different polarities are shown. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:215 / 225
页数:11
相关论文
共 47 条
[1]   QUANTITATIVE CHARACTERIZATION OF POLYCHLORINATED BIPHENYL MIXTURES (AROCLOR-1248, AROCLOR-1254 AND AROCLOR-1260) BY GAS-CHROMATOGRAPHY USING CAPILLARY COLUMNS [J].
ALBRO, PW ;
CORBETT, JT ;
SCHROEDER, JL .
JOURNAL OF CHROMATOGRAPHY, 1981, 205 (01) :103-111
[2]  
BUSH B, 1982, J ASSOC OFF ANA CHEM, V65, P555
[3]   THE ROUTINE DETERMINATION OF PCBS IN WASTE AUTOMOTIVE ENGINE OILS [J].
CANALS, A ;
FORTEZA, R ;
CERDA, V .
CHROMATOGRAPHIA, 1992, 34 (1-2) :35-40
[4]   Determination of retention indices of polychlorobiphenyls by using other compounds detectable by electron-capture detection or selected polychlorobiphenyls as the reference series [J].
Castello, G ;
Testini, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (02) :241-249
[5]   CORRELATIONS BETWEEN PHYSICAL PROPERTIES OF HALOGENATED ALKANES AND THEIR GAS-CHROMATOGRAPHIC BEHAVIOR ON POLAR AND NONPOLAR STATIONARY PHASES [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1973, 76 (02) :293-306
[6]   CORRELATIONS BETWEEN MOLECULAR STRUCTURE AND PHYSICAL PROPERTIES OF ALKYL IODIDES AND THEIR RETENTION INDICES [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1971, 58 (01) :127-&
[7]   FAST EVALUATION OF THE POLARITY OF GAS-CHROMATOGRAPHIC COLUMNS USING THE DIFFERENCE IN APPARENT CARBON NUMBER OF LINEAR ALKANES AND ALCOHOLS WITH THE SAME RETENTION [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 623 (02) :289-295
[8]   EVALUATION OF THE POLARITY OF PACKED AND CAPILLARY COLUMNS BY DIFFERENT CLASSIFICATION METHODS [J].
CASTELLO, G ;
DAMATO, G ;
VEZZANI, S .
JOURNAL OF CHROMATOGRAPHY, 1993, 646 (02) :361-368
[9]   GAS CHROMATOGRAPHY OF ALKYL IODIDES .2. INFLUENCE OF STRUCTURE ON RETENTION TIME AND SENSITIVITY TO ELECTRON CAPTURE DETECTOR [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1971, 54 (02) :157-&
[10]  
CASTELLO G, 1996, EUR 9 EUR C AN CHEM