Analyte- and matrix-dependent elemental response variations in laser ablation inductively coupled plasma mass spectrometry - Part 2. Implications for multi-element analyses

被引:48
作者
Rodushkin, I
Axelsson, MD
Malinovsky, D
Baxter, DC
机构
[1] Analyt AB, S-97775 Lulea, Sweden
[2] Lulea Univ Technol, Div Appl Geol, S-97187 Lulea, Sweden
[3] Lulea Univ Technol, Div Inorgan Chem, S-97187 Lulea, Sweden
关键词
D O I
10.1039/b205547c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Given that laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has the potential to directly determine the concentrations of some 80 elements in solid samples, the fact that most applications are limited to considerably smaller numbers of analytes is indicative of the inherent problems with calibration. These stem from elemental response variations, both between analytes in any given sample and between matrices for any given analyte. Although response variations are often attributed to differences in ablation or transport efficiencies, there have also been indications that some degree of elemental fractionation may occur in the ICP. The results of the present investigations demonstrate that the ICP is the predominant source of fractionation, and thus response variations are related to the thermodynamic properties of the elements and their host particles. By studying analyte response as a function of carrier gas flow rate (so called flow rate plots) in 16 matrices, patterns in the behaviour of the elements in LA-ICP-MS could be clearly discerned and used for classification. Three groups of elements displaying consistent behavioural patterns over all matrices were identified from these studies: Group A, comprising refractory elements with high oxide bond dissociation enthalpies; Group B, including the rare and heavier alkaline earth (Ca, Sr, Ba) elements; and Group C, consisting of volatile or low mass elements. As each group exhibits decidedly different optimum flow rates and flow rate plot shapes which, with the exception of the group C elements, also depend on the matrix, the utility of LA-ICP-MS for multi-element analyses is severely compromised. In fact, quantitative determination of a wide range of analytes demands that calibration factors be established for at least one element from each group, as well as for all elements that could not be satisfactorily classified. This classification may serve as a guide in the selection of suitable internal standards for LA-ICP-MS, at least for certain groups of analytes. Examples are also given showing how flow rate plots can be employed to predict the adequacy of selected internal standards or solid standard materials for calibration.
引用
收藏
页码:1231 / 1239
页数:9
相关论文
共 64 条
[1]   ENTRAINMENT AND TRANSPORT OF LASER ABLATED PLUMES FOR SUBSEQUENT ELEMENTAL ANALYSIS [J].
ARROWSMITH, P ;
HUGHES, SK .
APPLIED SPECTROSCOPY, 1988, 42 (07) :1231-1239
[2]  
Axelsson MD, 2001, RRD PURE APPL ANALYT, V3, P27
[3]   Multielemental analysis of Mn-Fe nodules by ICP-MS:: optimisation of analytical method [J].
Axelsson, MD ;
Rodushkin, I ;
Ingri, J ;
Öhlander, B .
ANALYST, 2002, 127 (01) :76-82
[4]   Determination of major and trace elements in sphalerite using laser ablation double focusing sector field ICP-MS [J].
Axelsson, MD ;
Rodushkin, I .
JOURNAL OF GEOCHEMICAL EXPLORATION, 2001, 72 (02) :81-89
[5]   High spatial resolution analysis of ferromanganese concretions by LA-ICP-MS† [J].
Mikael D. Axelsson ;
Ilia Rodushkin ;
Douglas C. Baxter ;
Johan Ingri ;
Björn Öhlander .
Geochemical Transactions, 3 (1)
[6]   Analysis of soil and sediment samples by laser ablation inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Bi, M ;
Aucelio, RQ ;
Smith, BW ;
Winefordner, JD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) :19-26
[7]   Enhanced semiquantitative multi-analysis of trace elements in environmental samples using inductively coupled plasma mass spectrometry [J].
Bayon, MM ;
Alonso, JIG ;
Medel, AS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (04) :277-282
[8]   HOMOGENEITY AND EVALUATION OF THE NEW NIST LEAF CERTIFIED REFERENCE MATERIALS [J].
BECKER, DA .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1990, 26-7 :571-577
[9]   Determination of trace elements in geological samples by laser ablation inductively coupled plasma mass spectrometry [J].
Becker, JS ;
Dietze, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :429-434
[10]   Trace element microanalysis in iron meteorites by laser ablation ICPMS [J].
Campbell, AJ ;
Humayun, M .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :939-946