Sulfite determination using sulfite oxidase biosensor based glassy carbon electrode coated with thin mercury film

被引:54
作者
Dinckaya, Erhan
Sezginturk, Mustafa Kemal [1 ]
Akyilmaz, Erol
Ertas, F. Nil
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Izmir, Turkey
[2] Ege Univ, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
关键词
sulfite oxidase; sulfite; food additives; mercury thin film electrode; biosensor;
D O I
10.1016/j.foodchem.2006.04.006
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The preparation of sulfite biosensor by immobilization of sulfite oxidase on a glassy carbon electrode coated with mercury thin film is described. Dissolved oxygen can be readily reduced at the glassy carbon electrode coated with mercury thin film. The working principle of the biosensor was based on monitoring decrease in the peak current due to the depletion in dissolved oxygen concentration according to the reaction of sulfite oxidase. The biosensor allowed a low working potential of -0.24 V vs. Ag/AgCl. Immobilization parameters such as sulfite oxidase activity, gelatin amount, and glutaraldehyde percentage were investigated. The pH optimum of 7.0 was found when using phosphate buffer. Appropriate buffer concentration was found to be 0.05 M. Working temperature was accepted as 40 degrees C. The biosensor was stable at 40 degrees C for 3 h without loss of its initial activity. The calibration graph for the biosensor was linear between the concentration ranges of 2 x 10(-4)-2.8 x 10(-3) M sulfite. The results of sample analyses obtained with the biosensor agreed well with the enzymatic-spectrophotometric reference method. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1540 / 1544
页数:5
相关论文
共 11 条
[1]  
ANDERSON C, 1986, J ASSOC OFF ANA CHEM, V69, P14
[2]  
[Anonymous], 1986, FED REG
[3]  
[Anonymous], FED REG
[4]  
Cunnif P., 1995, OFFICIAL METHODS ANA, VII
[5]   DEVELOPMENT OF AN OPTICAL FLOW-THROUGH BIOSENSOR FOR THE DETERMINATION OF SULFITE IN ENVIRONMENTAL-SAMPLES [J].
DECASTRO, MDL ;
FERNANDEZROMERO, JM .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :281-287
[6]  
Ertas FN, 2000, TURK J CHEM, V24, P95
[7]   HIGH-PERFORMANCE ION CHROMATOGRAPHY DETERMINATION OF TOTAL SULFITES IN FOODSTUFFS [J].
RUIZ, E ;
SANTILLANA, MI ;
DEALBA, M ;
NIETO, MT ;
GARCIACASTELLANO, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (02) :447-456
[8]   A sulfite biosensor fabricated using electrodeposited polytyramine: application to wine analysis [J].
Situmorang, M ;
Hibbert, DB ;
Gooding, JJ ;
Barnett, D .
ANALYST, 1999, 124 (12) :1775-1779
[9]   The determination of the sulphite content of some foods and beverages by capillary electrophoresis [J].
Trenerry, VC .
FOOD CHEMISTRY, 1996, 55 (03) :299-303
[10]   Role of sulfite additives in wine induced asthma: Single dose and cumulative dose studies [J].
Vally, H ;
Thompson, PJ .
THORAX, 2001, 56 (10) :763-769