A micro-potentiometric hemoglobin immunosensor based on electropolymerized polypyrrole-gold nanoparticles composite

被引:57
作者
Qu, Lan [1 ,2 ]
Xia, Shanhong [1 ]
Bian, Chao [1 ]
Sun, Jizhou [1 ,2 ]
Han, Jinghong [1 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-immunosensor; Potentiometric; Polypyrrole (PPy); Gold nanoparticles (AuNP); Hemoglobin (Hb); Ion-sensitive field-effect transistors (ISFETs); GLUCOSE-OXIDASE; GLYCATED HEMOGLOBIN; AMPEROMETRIC BIOSENSOR; ELECTRODE; SENSOR; FILM; NANOCOMPOSITE; IMMOBILIZATION; NITRATE; GROWTH;
D O I
10.1016/j.bios.2008.07.077
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report a novel micro-potentiometric hemoglobin (Hb) immunosensor based on electrochemically synthesized polypyrrole (PPy)-gold nanoparticles (AuNPs) composite. PPy-AuNPs film with AuNPs uniformly distributed in it was deposited on gold electrode surface by a simple and direct procedure, without the addition of any nanoparticles or reducing agent. And this generic method makes it possible to deposite different polymers on miniaturized electrodes. With the existence of AuNPs, the antibody immobilization onto the electrode surface was facilitated. Morphology study by field emission scanning electron microscope (FE-SEM) confirms the presence of AuNPs in PPy. Based on an ion-sensitive field-effect transistors (ISFETs) integrated chip, a micro-potentiometric immunosensor for Hb and hemoglobin-A1c (HbA1c) has been constructed. The sensor response was linear over the concentration range 60-180 mu g/ml Hb and 4-18 mu g/ml HbA1c. The Hb concentration in whole blood samples has also been analysed, with a linear dose-response behavior between 125 and 197 mu g/ml and a sensitivity of 0.20 mV mu g(-1) ml. The measuring ranges of the developed Hb and HbA1c immunosensors meet the clinical demand for measuring the HbA1c/Hb ratio of 5-20%. This sensor results in simple and rapid differential measurement of Hb and HbA1c, and has great potential to become an inexpensive and portable device for monitoring of diabetes. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:3419 / 3424
页数:6
相关论文
共 30 条
  • [1] Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose
    Adeloju, SB
    Moline, AN
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) : 133 - 139
  • [2] BIOSYNTHESIS OF HUMAN HEMOGLOBIN A1C - SLOW GLYCOSYLATION OF HEMOGLOBIN INVIVO
    BUNN, HF
    HANEY, DN
    KAMIN, S
    GABBAY, KH
    GALLOP, PM
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1976, 57 (06) : 1652 - 1659
  • [3] Immediate feedback of HbA1c levels improves glycemic control in type I and insulin-treated type 2 diabetic patients
    Cagliero, E
    Levina, EV
    Nathan, DM
    [J]. DIABETES CARE, 1999, 22 (11) : 1785 - 1789
  • [4] Electrosynthesis and characterization of polypyrrole/Au nanocomposite
    Chen, Wei
    Li, Chang Ming
    Chen, Peng
    Sun, C. Q.
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (08) : 2845 - 2849
  • [5] Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode
    Chu, Xia
    Duan, Daxue
    Shen, Guoli
    Yu, Ruqin
    [J]. TALANTA, 2007, 71 (05) : 2040 - 2047
  • [6] Electrochemical thiocholine inhibition sensor based on biocatalytic growth of Au nanoparticles using chitosan as template
    Du, Dan
    Ding, Jiawang
    Cai, Jie
    Zhang, Aidong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (02) : 317 - 322
  • [7] Polypyrrole nanotube array sensor for enhanced adsorption of glucose oxidase in glucose biosensors
    Ekanayake, E. M. I. Mala
    Preethichandra, D. M. G.
    Kaneto, Keiichi
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 23 (01) : 107 - 113
  • [8] Synthesis and electrochemical applications of gold nanoparticles
    Guo, Shaojun
    Wang, Erkang
    [J]. ANALYTICA CHIMICA ACTA, 2007, 598 (02) : 181 - 192
  • [9] Development of a biosensor for glycated hemoglobin
    Halámek, J.
    Wollenberger, U.
    Stoecklein, W.
    Scheller, F. W.
    [J]. ELECTROCHIMICA ACTA, 2007, 53 (03) : 1127 - 1133
  • [10] Development of capacitance based immunosensors on mixed self-assembled monolayers
    Hays, HCW
    Millner, PA
    Prodromidis, MI
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02): : 1064 - 1070