The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide

被引:13
作者
Deckers, F
Corthouts, B
Nackaerts, Y
Ozsarlak, O
Parizel, PM
DeSchepper, AM
机构
[1] Department of Radiology, Universitair Ziekenhuis Antwerpen
关键词
MR imaging; liver; contrast media; liver neoplasms; superparamagnetic iron oxide particles;
D O I
10.1007/s003300050222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the value of low- vs high-field MR systems in the detection of focal liver lesions after IV administration of iron oxide particles. A prospective study was undertaken which included 20 patients with focal liver lesions on CT or US, or strong clinical suspicion of focal liver disease. Iron oxide particles were administered in an IV drip infusion over 30 min. Magnetic resonance imaging was subsequently performed on a 0.2 and a 1.5-T system. Both examinations were performed in one session. Turbo spin-echo T2-weighted sequences were used for further analysis (at 0.2 T: TR 4050 ms, TE 96 ms, 1.5 T: TR 3000 ms, TE 103 ms). After randomisation, images were analysed by two blinded readers. The evaluation included lesion counts, determination of lesion conspicuity and overall image quality (both graded on a scale 1-5). Quantitative analysis was performed on 29 lesions. Lesion-to-liver signal intensity and contrast-to-noise ratios (CNRs) were calculated. The total lesion count (cumulative counts for two observers) was 59 on the high-field system and 63 on the low-field system. Statistical analysis showed no significant difference. On both systems median value for lesion conspicuity was 3. No statistically significant difference was found. Global image quality was rated higher (p = 0.0017). Quantitative analysis showed no significant difference for lesion-to-liver signal intensity ratios or CNRs. Although subjective image quality is significantly better on the high-field system, this does not result in better lesion detection or better lesion conspicuity. No significant difference in objective quantitative parameters was found in our series.
引用
收藏
页码:887 / 892
页数:6
相关论文
共 19 条
[1]   LIVER-TUMORS IN CIRRHOSIS - EXPERIMENTAL-STUDY WITH SPIO-ENHANCED MR IMAGING [J].
CLEMENT, O ;
FRIJA, G ;
CHAMBON, C ;
SCHOUMANCLAYES, E ;
MOSNIER, JF ;
POUPON, MF ;
BALKAU, B .
RADIOLOGY, 1991, 180 (01) :31-36
[2]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[3]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[4]   ENHANCEMENT OF LIVER HEMANGIOMAS ON T1-WEIGHTED MR SE IMAGES BY SUPERPARAMAGNETIC IRON-OXIDE PARTICLES [J].
GRANGIER, C ;
TOURNIAIRE, J ;
MENTHA, G ;
SCHIAU, R ;
HOWARTH, N ;
CHACHUAT, A ;
GROSSHOLZ, M ;
TERRIER, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) :888-896
[5]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366
[6]   DETECTION OF FOCAL LIVER-LESIONS WITH SUPERPARAMAGNETIC IRON-OXIDE - VALUE OF STIR AND SE IMAGING [J].
HALAVAARA, JT ;
LAMMINEN, AE ;
BONDESTAM, S ;
STANDERTSKJOLDNORDENSTAM, CG ;
HAMBERG, LM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) :897-904
[7]  
KREFT B, 1994, EUR RADIOL, V4, P106
[8]   QUANTITATION OF MR RELAXATION EFFECTS OF IRON-OXIDE PARTICLES IN LIVER AND SPLEEN [J].
MAJUMDAR, S ;
ZOGHBI, S ;
POPE, CF ;
GORE, JC .
RADIOLOGY, 1988, 169 (03) :653-655
[9]   DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T [J].
MARCHAL, G ;
VANHECKE, P ;
DEMAEREL, P ;
DECROP, E ;
KENNIS, C ;
BAERT, AL ;
VANDERSCHUEREN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :771-775
[10]   LOW-FIELD VERSUS HIGH-FIELD MR-IMAGING OF THE KNEE - A COMPARISON OF SIGNAL BEHAVIOR AND DIAGNOSTIC PERFORMANCE [J].
PARIZEL, PM ;
DIJKSTRA, HAJ ;
GEENEN, GPJ ;
KINT, PAM ;
VERSTEYLEN, RJ ;
VANWIECHEN, PJ ;
DESCHEPPER, AM .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 19 (02) :132-138