Accuracy of machine milling and spark erosion with a CAD/CAM system

被引:55
作者
Andersson, M
Carlsson, L
Persson, M
Bergman, B
机构
[1] UMEA UNIV,FAC ODONTOL,DEPT PROSTHET DENT,S-90187 UMEA,SWEDEN
[2] NOBEL BIOCARE,AB PROCERA BUSINESS AREA,PROCERA DEV,GOTHENBURG,SWEDEN
关键词
D O I
10.1016/S0022-3913(96)90305-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A method for manufacturing crowns and fixed partial dentures based on CAD/CAM has been developed as an alternative to the lost wax technique and the casting of an alloy, In this process two steps are included: milling and spark erosion. The computer-assisted design (CAD) relies heavily on the accuracy of the milling and spark erosion processes to achieve a clinically acceptable restoration, These two processes must be able to produce the crown data generated in the CAD files. This study evaluated the accuracy of the Procera CAD/CAM system in creating specific geometric bodies that were compared with the known dimensions in the CAD files for these bodies, The manufacturing errors of milling (ellipse +/-6.5 mu m, square +/-3.4 mu m, and cylinder +/-5.8 mu m) and spark erosion (ellipse +/-8.6 mu m and square +/-10.4 mu m) were determined. The accuracy of this manufacturing process demonstrated that this system was capable of producing a crown with a clinically accepted range for marginal opening gap dimension of less than 100 mu m.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 19 条
[1]   A NEW ALL-CERAMIC CROWN - A DENSE-SINTERED, HIGH-PURITY ALUMINA COPING WITH PORCELAIN [J].
ANDERSSON, M ;
ODEN, A .
ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (01) :59-64
[2]   CLINICAL-RESULTS WITH TITANIUM CROWNS FABRICATED WITH MACHINE DUPLICATION AND SPARK EROSION [J].
ANDERSSON, M ;
BERGMAN, B ;
BESSING, C ;
ERICSON, G ;
LUNDQUIST, P ;
NILSON, H .
ACTA ODONTOLOGICA SCANDINAVICA, 1989, 47 (05) :279-286
[3]   A 2-YEAR FOLLOW-UP-STUDY OF TITANIUM CROWNS [J].
BERGMAN, B ;
BESSING, C ;
ERICSON, G ;
LUNDQUIST, P ;
NILSON, H ;
ANDERSSON, M .
ACTA ODONTOLOGICA SCANDINAVICA, 1990, 48 (02) :113-117
[4]  
DURET F, 1992, ARTET TECHNIQUE DENT, V4, P241
[5]   THE FIT OF PROCERA TITANIUM CROWNS - AN INVITRO AND CLINICAL-STUDY [J].
KARLSSON, S .
ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (03) :129-134
[6]  
KORBER E, 1986, DEUT ZAHNAERZTL Z, V41, P525
[7]  
Kunzelmann K H, 1990, Dtsch Zahnarztl Z, V45, P277
[8]  
MALEY K, 1995, P 52 ANN C ANTEC 94
[9]   ESTIMATION OF CEMENT FILM THICKNESS BY AN IN-VIVO TECHNIQUE [J].
MCLEAN, JW ;
FRAUNHOFER, JA .
BRITISH DENTAL JOURNAL, 1971, 131 (03) :107-+
[10]  
Mormann W H, 1989, Quintessence Int, V20, P329