Energy response of an aluminium oxide detector in kilovoltage and megavoltage photon beams: An EGSnrc Monte Carlo simulation study

被引:18
作者
Agyingi, EO [1 ]
Mobit, PN
Sandison, GA
机构
[1] Univ Calgary, Dept Oncol, Calgary, AB T2N 1N4, Canada
[2] Tom Baker Canc Clin, Calgary, AB T2N 1N4, Canada
[3] Harper Univ Hosp, Gershenson Radiat Oncol Ctr, Detroit, MI 48201 USA
[4] Wayne State Univ, Detroit, MI 48201 USA
[5] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
关键词
D O I
10.1093/rpd/nci329
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A Monte Carlo study of the energy response of an aluminium oxide (Al2O3) detector in kilovoltage and megavoltage photon beams relative to Co-60 gamma rays has been performed using EGSnrc Monte Carlo simulations. The sensitive volume of the Al2O3 detector was simulated as a disc of diameter 2.85 mm and thickness 1 mm. The phantom material was water and the irradiation depth chosen was 2.0 cm in kilovoltage photon beams and 5.0 cm in megavoltage photon beams. The results show that the energy response of the Al2O3 detector is constant within 3% for photon beam energies in the energy range of Co-60 gamma rays to 25 MV X rays. However, the Al2O3 detector shows an enhanced energy response for kilovoltage photon beams, which in the case of 50 kV X rays is 3.2 times higher than that for Co-60 gamma rays. There is essentially no difference in the energy responses of LiF and Al2O3 detectors irradiated in megavoltage photon beams when these Al2O3 results are compared with literature data for LiF thermoluminescence detectors. However, the Al2O3 detector has a much higher enhanced response compared with LiF detectors in kilovoltage X-ray beams, more than twice as much for the case of 50 kV X rays.
引用
收藏
页码:28 / 31
页数:4
相关论文
共 21 条
[1]  
AKSELROD MS, 1993, RADIAT PROT DOSIM, V47, P159
[2]  
Johns H.E., 1983, PHYS RADIOLOGY
[3]   MATERIALS FOR THERMOLUMINESCENT DOSE DETECTORS AND PHOTON RADIATION ENERGY DETECTORS INTENDED FOR INTERCOMPARISON PROCEDURES OF RADIATION-THERAPY UNITS [J].
KALMYKOV, LZ .
MEDICAL PHYSICS, 1994, 21 (11) :1715-1719
[4]  
KAWRAKOW I, 2002, PIRS701 NRCC
[5]   Some new data on thermoluminescence properties of dosimetric alpha-Al2O3 crystals [J].
Kortov, V ;
Milman, I .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :179-184
[6]   Development of a personal dosimetry system based on optically stimulated luminescence of α-Al2O3:C for mixed radiation fields [J].
Lee, SY ;
Lee, KJ .
APPLIED RADIATION AND ISOTOPES, 2001, 54 (04) :675-685
[7]   ANNEALING CHARACTERISTICS AND NATURE OF TRAPS IN AL2O3 THERMOLUMINESCENT PHOSPHOR [J].
MEHTA, SK ;
SENGUPTA, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (05) :863-872
[8]   GAMMA DOSIMETRY WITH AL2O3 THERMOLUMINESCENT PHOSPHOR [J].
MEHTA, SK ;
SENGUPTA, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (06) :955-964
[9]   The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments [J].
Mobit, PN ;
Mayles, P ;
Nahum, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03) :387-398
[10]   A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams [J].
Mobit, PN ;
Nahum, AE ;
Mayles, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2015-2032