A novel methodology for in vivo endoscopic phenotyping of colorectal cancer based on real-time analysis of the mucosal lipidome: a prospective observational study of the iKnife

被引:84
作者
Alexander, James [1 ]
Gildea, Louise [1 ]
Balog, Julia [2 ]
Speller, Abigail [3 ]
McKenzie, James [1 ]
Muirhead, Laura [1 ]
Scott, Alasdair [1 ]
Kontovounisios, Christos [5 ]
Rasheed, Shanawaz [5 ]
Teare, Julian [1 ]
Hoare, Jonathan [4 ]
Veselkov, Kirill [1 ]
Goldin, Robert [3 ]
Tekkis, Paris [5 ]
Darzi, Ara [1 ]
Nicholson, Jeremy [1 ]
Kinross, James [1 ]
Takats, Zoltan [1 ]
机构
[1] Imperial Coll London, St Marys Hosp, Dept Surg & Canc, Praed St, London NW1 1SQ, England
[2] Waters Corp, Wilmslow, Cheshire, England
[3] Imperial Coll London, Dept Histopathol, London, England
[4] Imperial Healthcare NHS Trust, Dept Gastroenterol, London, England
[5] Royal Marsden Hosp NHS Trust, Dept Colorectal Surg, London, England
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2017年 / 31卷 / 03期
基金
欧洲研究理事会;
关键词
Rapid evaporative ionization mass spectrometry; Colorectal cancer; Metabolic; IONIZATION MASS-SPECTROMETRY; TISSUE; IDENTIFICATION; METABOLISM; POLYPS;
D O I
10.1007/s00464-016-5121-5
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
This pilot study assessed the diagnostic accuracy of rapid evaporative ionization mass spectrometry (REIMS) in colorectal cancer (CRC) and colonic adenomas. Patients undergoing elective surgical resection for CRC were recruited at St. Mary's Hospital London and The Royal Marsden Hospital, UK. Ex vivo analysis was performed using a standard electrosurgery handpiece with aspiration of the electrosurgical aerosol to a Xevo G2-S iKnife QTof mass spectrometer (Waters Corporation). Histological examination was performed for validation purposes. Multivariate analysis was performed using principal component analysis and linear discriminant analysis in Matlab 2015a (Mathworks, Natick, MA). A modified REIMS endoscopic snare was developed (Medwork) and used prospectively in five patients to assess its feasibility during hot snare polypectomy. Twenty-eight patients were recruited (12 males, median age 71, range 35-89). REIMS was able to reliably distinguish between cancer and normal adjacent mucosa (NAM) (AUC 0.96) and between NAM and adenoma (AUC 0.99). It had an overall accuracy of 94.4 % for the detection of cancer versus adenoma and an adenoma sensitivity of 78.6 % and specificity of 97.3 % (AUC 0.99) versus cancer. Long-chain phosphatidylserines (e.g., PS 22:0) and bacterial phosphatidylglycerols were over-expressed on cancer samples, while NAM was defined by raised plasmalogens and triacylglycerols expression and adenomas demonstrated an over-expression of ceramides. REIMS was able to classify samples according to tumor differentiation, tumor budding, lymphovascular invasion, extramural vascular invasion and lymph node micrometastases (AUC's 0.88, 0.87, 0.83, 0.81 and 0.81, respectively). During endoscopic deployment, colonoscopic REIMS was able to detect target lipid species such as ceramides during hot snare polypectomy. REIMS demonstrates high diagnostic accuracy for tumor type and for established histological features of poor prognostic outcome in CRC based on a multivariate analysis of the mucosal lipidome. REIMS could augment endoscopic and imaging technologies for precision phenotyping of colorectal cancer.
引用
收藏
页码:1361 / 1370
页数:10
相关论文
共 19 条
[1]
In Vivo Endoscopic Tissue Identification by Rapid Evaporative Ionization Mass Spectrometry (REIMS) [J].
Balog, Julia ;
Kumar, Sacheen ;
Alexander, James ;
Golf, Ottmar ;
Huang, Juzheng ;
Wiggins, Tom ;
Abbassi-Ghadi, Nima ;
Enyedi, Attila ;
Kacska, Sandor ;
Kinross, James ;
Hanna, George B. ;
Nicholson, Jeremy K. ;
Takats, Zoltan .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (38) :11059-11062
[2]
Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry [J].
Balog, Julia ;
Sasi-Szabo, Laszlo ;
Kinross, James ;
Lewis, Matthew R. ;
Muirhead, Laura J. ;
Veselkov, Kirill ;
Mirnezami, Reza ;
Dezso, Balazs ;
Damjanovich, Laszlo ;
Darzi, Ara ;
Nicholson, Jeremy K. ;
Takats, Zoltan .
SCIENCE TRANSLATIONAL MEDICINE, 2013, 5 (194)
[3]
Identification of Biological Tissues by Rapid Evaporative Ionization Mass Spectrometry [J].
Balog, Julia ;
Szaniszlo, Tamas ;
Schaefer, Karl-Christian ;
Denes, Julia ;
Lopata, Antal ;
Godorhazy, Lajos ;
Szalay, Daniel ;
Balogh, Lajos ;
Sasi-Szabo, Laszlo ;
Toth, Mikos ;
Takats, Zoltan .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7343-7350
[4]
Rapid Evaporative Ionization Mass Spectrometry Imaging Platform for Direct Mapping from Bulk Tissue and Bacterial Growth Media [J].
Golf, Ottmar ;
Strittmatter, Nicole ;
Karancsi, Tamas ;
Pringle, Steven D. ;
Speller, Abigail V. M. ;
Mroz, Anna ;
Kinrosss, James M. ;
Abbassi-Ghadi, Nima ;
Jones, Emrys A. ;
Takats, Zoltan .
ANALYTICAL CHEMISTRY, 2015, 87 (05) :2527-2534
[5]
Trouble in Paris (Classification): Polyp Morphology Is in The Eye of The Beholder [J].
Gupta, Samir .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 (01) :188-191
[6]
Characterization of surgical aerosols by the compact single-particle mass spectrometer LAMPAS 3 [J].
Hinz, K. -P. ;
Gelhausen, E. ;
Schaefer, K. -C. ;
Takats, Z. ;
Spengler, B. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (10) :3165-3172
[7]
1H HR-MAS NMR Spectroscopy of Tumor-Induced Local Metabolic "Field-Effects" Enables Colorectal Cancer Staging and Prognostication [J].
Jimenez, Beatriz ;
Mirnezami, Reza ;
Kinross, James ;
Cloarec, Olivier ;
Keun, Hector C. ;
Holmes, Elaine ;
Goldin, Robert D. ;
Ziprin, Paul ;
Darzi, Ara ;
Nicholson, Jeremy K. .
JOURNAL OF PROTEOME RESEARCH, 2013, 12 (02) :959-968
[8]
Feasibility and Accuracy of Confocal Endomicroscopy in Comparison With Narrow-Band Imaging and Chromoendoscopy for the Differentiation of Colorectal Lesions [J].
Kuiper, T. ;
van den Broek, F. J. C. ;
van Eeden, S. ;
Fockens, P. ;
Dekker, E. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 (04) :543-550
[9]
Sphingolipid metabolism in colorectal adenomas varies depending on histological architecture of polyps and grade of nuclear dysplasia [J].
Kurek, Krzysztof ;
Lukaszuk, Bartlomiej ;
Swidnicka-Siergiejko, Agnieszka ;
Rogalski, Pawel ;
Wroblewski, Eugeniusz ;
Chabowski, Adrian ;
Dabrowski, Andrzej ;
Zendzian-Piotrowska, Malgorzata .
LIPIDS, 2015, 50 (04) :349-358
[10]
Narrow band imaging to differentiate neoplastic and non-neoplastic colorectal polyps in real time: a meta-analysis of diagnostic operating characteristics [J].
McGill, Sarah K. ;
Evangelou, Evangelos ;
Ioannidis, John P. A. ;
Soetikno, Roy M. ;
Kaltenbach, Tonya .
GUT, 2013, 62 (12) :1704-1713