Determination of four benzodiazepine residues in pork using multiwalled carbon nanotube solid-phase extraction and gas chromatography-mass spectrometry

被引:74
作者
Wang, Liping
Zhao, Haixiang
Qiu, Yueming
Zhou, Zhiqiang [1 ]
机构
[1] China Agr Univ, Coll Sci, Beijing 100094, Peoples R China
[2] Chinase Acad Inspect & Quarantine, Inspect Technol & Equipment Inst, Beijing 100025, Peoples R China
[3] Hebei N Coll, Dept Basic Agr Sci, Zhangjiakou 075131, Peoples R China
关键词
multiwalled carbon nanotubes; solid-phase extraction; GC-MS; benzodiazepines; pork;
D O I
10.1016/j.chroma.2006.09.088
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid-phase extraction (SPE)/GC-MS method using multiwalled carbon nanotubes (MWCNTs) was developed for the determination of four benzodiazepine residues including diazepam, estazolam, alprazolam and triazolam in pork. The analytes were extracted by ultrasonic assistant extraction using acetonittile, concentrated and purified by MWCNTs packed cartridge, and determined by GC-MS. Ultrasonic extraction conditions, which included temperature, time, power, and solvent volume, were optimized. Comparative studies showed that MWCNTs were superior to C18 for the adsorption of drugs. Parameters influencing SPE efficiency, such as sample amounts, variety and volume of the eluent, were also optimized. Electron ionization (El) operating in time program-selected ion monitoring mode (SIM) was used for GC-MS identification. The analytes were quantified with external standard calibration curve method. Lower limit of detection and quantification was obtained by the new method. Linear calibration curves were obtained in the concentration range from 10 ng/mL to 500 ng/mL for diazepam and from 20 ng/n-tL to 1000 ng/mL for estazolam, alprazolarn and triazolam with calibration coefficients of 0.99 and above. The average recoveries for the four benzodiazepines spiked in pork were 75% to 104% and their relative standard deviations were between 1.3% and 10%. The limits of detection were 2 mu g/kg for diazeparn and 5 mu g/kg for estazolam, alprazolarn and triazolam in pork, respectively. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 35 条
[1]   ANALYSIS OF URINARY BENZODIAZEPINES USING SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLACK, DA ;
CLARK, GD ;
HAVER, VM ;
GARBIN, JA ;
SAXON, AJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (04) :185-188
[2]   Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol a, 4-n-nonylphenol, and 4-tert-octylphenol [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
Zhou, QX .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2517-2521
[3]   Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
Zhou, QX .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :149-156
[4]   Miniaturized capillary electrophoresis system with a carbon nanotube microelectrode for rapid separation and detection of thiols [J].
Chen, G ;
Zhang, LY ;
Wang, J .
TALANTA, 2004, 64 (04) :1018-1023
[5]   Solution properties of single-walled carbon nanotubes [J].
Chen, J ;
Hamon, MA ;
Hu, H ;
Chen, YS ;
Rao, AM ;
Eklund, PC ;
Haddon, RC .
SCIENCE, 1998, 282 (5386) :95-98
[6]  
Dai HJ, 2000, PHYS WORLD, V13, P43
[7]   TRANQUILIZING EFFECTS OF DIAZEPAM IN PIGS SUBJECTED TO A PUNISHMENT PROCEDURE [J].
DANTZER, R ;
ROCA, M .
PSYCHOPHARMACOLOGIA, 1974, 40 (03) :235-240
[8]  
DANTZER R, 1975, Annales de Recherches Veterinaires, V6, P165
[9]   Carbon nanotubes as molecular quantum wires [J].
Dekker, C .
PHYSICS TODAY, 1999, 52 (05) :22-28
[10]   URINALYSIS OF ALPHA-HYDROXYALPRAZOLAM, ALPHA-HYDROXYTRIAZOLAM, AND OTHER BENZODIAZEPINE COMPOUNDS BY GC/EIMS [J].
DICKSON, PH ;
MARKUS, W ;
MCKERNAN, J ;
NIPPER, HC .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (02) :67-71