Rapid biomonitoring of heterocyclic aromatic amines in human urine by tandem solvent solid phase extraction liquid chromatography electrospray ionization mass spectrometry

被引:42
作者
Holland, RD
Taylor, J
Schoenbachler, L
Jones, RC
Freeman, JP
Miller, TW
Lake, BG
Gooderham, NJ
Turesky, RJ
机构
[1] Natl Ctr Toxicol Res, Div Chem, Jefferson, AR 72079 USA
[2] BIBRA Int, Carshalton SM5 4DS, Surrey, England
[3] Univ London Imperial Coll Sci Technol & Med, Div Biomed Sci, London SW7 2AZ, England
关键词
D O I
10.1021/tx049910a
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A rapid and facile tandem solvent solid phase extraction method was established to isolate the heterocyclic aromatic amines (HAAs) 2-amino-3,8-dimethylimidazo[4,5-f] quinoxaline (8-MeIQx), 2-amino-3,4,8-trimethylimidazo[4,5-f] quinoxaline, 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine, and 2-amino-9H-pyrido[2,3-b]indole from urine. The HAAs were separated by reversed phase liquid chromatography and quantified by electrospray ionization tandem mass spectrometry (ESI/MS/MS) using selected reaction monitoring. The limits of detection and quantitation of these HAAs approached 1-3 and 2-8 pg/mL, respectively, using only 0.3 mL of urine for analysis. Full product ion spectra were acquired to corroborate analyte identities. The pretreatment of urine from human volunteers that had consumed a grilled beef meal with acid or base at 70 degreesC increased the concentration of HAAs by as much as 6-fold, indicating the presence of phase II conjugates of the parent compounds. HAAs containing an N-methylimidazole moiety undergo facile cleavage of the N-methyl group under collision-induced dissociation conditions, and MS/MS analysis in the constant neutral loss scan mode monitoring the transition [M + H](+) --> [M + H - CH3.](+) revealed the presence of two other HAAs. 2-Amino-3-methylimidazo [4,5-f] quinoxaline (IQx) was identified by coelution of the analyte with synthetic IQx and by acquisition of the product ion spectrum. The second HAA was present in a relatively high abundance in urine. The molecule had the same nominal mass as 8-MeIQx (MH+ at m/z 214), and the product ion spectrum was similar to that of 8-MeIQx. This novel HAA was also found in the grilled meat consumed by the volunteers at a concentration of 8 parts per billion. The accurate mass measurement and product ion spectrum of this molecule by ESI quadrupole time-of-flight mass spectrometry revealed that it was an isomer of 8-MeIQx. This tandem solvent solid phase extraction LC/ESI/MS/MS procedure may be used to rapidly assess the daily exposure to a variety of HAAs in urine.
引用
收藏
页码:1121 / 1136
页数:16
相关论文
共 59 条
[1]   Evaluation of different liquid chromatography-electrospray mass spectrometry systems for the analysis of heterocyclic amines [J].
Barceló-Barrachina, E ;
Moyano, E ;
Puignou, L ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :67-78
[2]   Investigation of interaction between N-acetyltransferase 2 and heterocyclic amines as potential risk factors for colorectal cancer [J].
Barrett, JH ;
Smith, G ;
Waxman, R ;
Gooderham, N ;
Lightfoot, T ;
Garner, RC ;
Augustsson, K ;
Wolf, CR ;
Bishop, DT ;
Forman, D .
CARCINOGENESIS, 2003, 24 (02) :275-282
[3]   ISOLATION AND IDENTIFICATION OF MUTAGENS FROM A FRIED NORWEGIAN MEAT PRODUCT [J].
BECHER, G ;
KNIZE, MG ;
NES, IF ;
FELTON, JS .
CARCINOGENESIS, 1988, 9 (02) :247-253
[4]  
Boobis AR, 1996, ARCH TOX S, V18, P286
[5]   HUMAN CYTOCHROME P-450PA (P-450IA2), THE PHENACETIN O-DEETHYLASE, IS PRIMARILY RESPONSIBLE FOR THE HEPATIC 3-DEMETHYLATION OF CAFFEINE AND N-OXIDATION OF CARCINOGENIC ARYLAMINES - (AROMATIC-AMINES HETEROCYCLIC AMINES CARCINOGEN METABOLISM) [J].
BUTLER, MA ;
IWASAKI, M ;
GUENGERICH, FP ;
KADLUBAR, FF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (20) :7696-7700
[6]   Effects of carnosine on volatile generation from Maillard reaction of ribose and cysteine [J].
Chen, Y ;
Ho, CT .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (08) :2372-2376
[7]   Determination of heterocyclic aromatic amines in food products: Automation of the sample preparation method prior to HPLC and HPLC-MS quantification [J].
Fay, LB ;
Ali, S ;
Gross, GA .
MUTATION RESEARCH-FUNDAMENTAL AND MOLECULAR MECHANISMS OF MUTAGENESIS, 1997, 376 (1-2) :29-35
[8]  
Felton J. S., 2000, Food borne carcinogens: heterocyclic amines., P31
[9]   MUTAGENIC ACTIVITY OF HETEROCYCLIC AMINES IN COOKED FOODS [J].
FELTON, JS ;
KNIZE, MG ;
DOLBEARE, FA ;
WU, R .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1994, 102 :201-204
[10]   Human exposure to heterocyclic amine food mutagens/carcinogens: Relevance to breast cancer [J].
Felton, JS ;
Knize, MG ;
Salmon, CP ;
Malfatti, MA ;
Kulp, KS .
ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2002, 39 (2-3) :112-118