Middle cerebral artery (MCA) susceptibility sign at susceptibility-based perfusion MR imaging:: Clinical importance and comparison with hyperdense MCA sign at CT

被引:123
作者
Flacke, S
Urbach, H
Keller, E
Träber, F
Hartmann, A
Textor, J
Gieseke, J
Block, W
Folkers, PJM
Schild, HH
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
[2] Univ Bonn, Dept Neurol, D-53105 Bonn, Germany
[3] Philips Med Syst, Best, Netherlands
关键词
blood vessels; MR; brain; CT; brain infarction; computed tomography (CT); comparative studies; embolism; magnetic resonance (MR); diffusion study; vascular studies;
D O I
10.1148/radiology.215.2.r00ma09476
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To describe the radiologic findings of susceptibility changes in acute middle cerebral artery (MCA) thromboembolism detected with three-dimensional (3D) susceptibility-based perfusion magnetic resonance (MR) imaging and to compare the detectability and clinical value of this sign with those of the hyperdense MCA sign at computed tomography (CT). MATERIALS AND METHODS: Twenty-three patients (mean age, 55 years) underwent CT and MR imaging within the first 6 hours after the onset of acute MCA stroke. The hyperdense MCA sign at CT and the presence of susceptibility changes in acute thromboembolism as depicted on T2*-weighted 3D perfusion MR images were assessed. The presence of each sign was correlated with clinical presentation. RESULTS: The sensitivity of the hyperdense MCA sign at CT was 54% (negative predictive value, 71%) compared with 82% (negative predictive value, 86%) for the susceptibility changes at MR imaging. There were no false-positive CT or MR readings. The presence of the MCA susceptibility sign correlated positively with the initial clinical presentation (chi(2) = 7.987, P = .009, Spearman p = 0.589). However, neither of the signs was a predictor for clinical outcome in cases of spontaneous MCA stroke. CONCLUSION: In addition to the information traditionally provided with reconstructed perfusion parameter maps, 3D susceptibility-based perfusion MR images allow the identification of acute MCA thromboembolism with a sensitivity higher than that of CT.
引用
收藏
页码:476 / 482
页数:7
相关论文
共 35 条
[11]   PREVALENCE AND SIGNIFICANCE OF HYPERDENSE MIDDLE CEREBRAL-ARTERY IN ACUTE STROKE [J].
LEYS, D ;
PRUVO, JP ;
GODEFROY, O ;
RONDEPIERRE, P ;
LECLERC, X .
STROKE, 1992, 23 (03) :317-324
[12]   A FUNCTIONAL MRI TECHNIQUE COMBINING PRINCIPLES OF ECHO-SHIFTING WITH A TRAIN OF OBSERVATIONS (PRESTO) [J].
LIU, GY ;
SOBERING, G ;
DUYN, J ;
MOONEN, CTW .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) :764-768
[13]   Clinical utility of diffusion-weighted magnetic resonance imaging in the assessment of ischemic stroke [J].
Lutsep, HL ;
Albers, GW ;
DeCrespigny, A ;
Kamat, GN ;
Marks, MP ;
Moseley, ME .
ANNALS OF NEUROLOGY, 1997, 41 (05) :574-580
[14]  
MOONEN CTW, 1992, MAGNET RESON MED, V30, P68
[15]   High resolution measurement of cerebral blood flow using intravascular tracer bolus passages .1. Mathematical approach and statistical analysis [J].
Ostergaard, L ;
Weisskoff, RM ;
Chesler, DA ;
Gyldensted, C ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :715-725
[16]  
PRESSMAN BD, 1987, AM J NEURORADIOL, V8, P645
[17]   Regional ischemia and ischemic injury in patients with acute middle cerebral artery stroke as defined by early diffusion-weighted and perfusion-weighted MRI [J].
Rordorf, G ;
Koroshetz, WJ ;
Copen, WA ;
Cramer, SC ;
Schaefer, PW ;
Budzik, RF ;
Schwamm, LH ;
Buonanno, F ;
Sorensen, AG ;
Gonzalez, G .
STROKE, 1998, 29 (05) :939-943
[18]   CONTRAST AGENTS AND CEREBRAL HEMODYNAMICS [J].
ROSEN, BR ;
BELLIVEAU, JW ;
BUCHBINDER, BR ;
MCKINSTRY, RC ;
PORKKA, LM ;
KENNEDY, DN ;
NEUDER, MS ;
FISEL, CR ;
ARONEN, HJ ;
KWONG, KK ;
WEISSKOFF, RM ;
COHEN, MS ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :285-292
[19]   MIDDLE CEREBRAL-ARTERY OCCLUSION - CORRELATION OF COMPUTED-TOMOGRAPHY AND ANGIOGRAPHY WITH CLINICAL OUTCOME [J].
SAITO, I ;
SEGAWA, H ;
SHIOKAWA, Y ;
TANIGUCHI, M ;
TSUTSUMI, K .
STROKE, 1987, 18 (05) :863-868
[20]  
SOERENSEN AG, 1996, RADIOLOGY, V199, P391