Contribution of early lumen loss after balloon angioplasty for in-stent restenosis to lumen loss at follow-up

被引:1
作者
Fujii, K
Masutani, M
Kobayashi, Y
Tateishi, J
Kawasaki, D
Ohyanagi, M
Mintz, GS
Leon, MB
机构
[1] Lenox Hill Heart & Vasc Inst, Cardiac Res Fdn, New York, NY 10022 USA
[2] Hyogo Med Univ, Dept Internal Med, Div Cardiovasc, Nishinomiya, Hyogo, Japan
关键词
intravascular ultrasound; restenosis; stent;
D O I
10.1002/ccd.20097
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The treatment of in-stent restenosis using balloon angioplasty alone often produces excellent early results, but is associated with high rate of recurrence. Previous studies have demonstrated significant tissue reintrusion shortly after the treatment of in-stent restenosis with balloon angioplasty. The study was designed to elucidate the contribution of early lumen loss 6 hr after balloon angioplasty to lumen loss at follow-up. We prospectively performed quantitative coronary angiography and intravascular ultrasound in 12 patients with in-stent restenosis before intervention, after the final procedure, 6 hr later (5.6 +/- 1.4 hr), and at follow-up (7.7 +/- 2.3 months). Compared with immediately after balloon angioplasty, by 6 hr postintervention, the minimum lumen diameter (MLD) and lumen cross-sectional area had decreased significantly (2.48 +/- 0.44 to 2.01 +/- 0.57 mm, P = 0.01, and 7.0 +/- 1.2 to 5.5 +/- 1.4 mm(2), p = 0.004, respectively). Furthermore, the MILD decreased further between 6 hr postintervention and long-term follow-up (2.01 +/- 0.57 to 1.55 +/- 0.64 mm; P = 0.001). Patients who showed recurrence of restenosis at follow-up had greater early lumen loss than patients without recurrence of restenosis (0.71 +/- 0.31 vs. 0.23 +/- 0.13 mm; P = 0.006). Diffuse lesions had greater early lumen loss compared to focal lesions (0.75 +/- 0.35 vs. 0.28 +/- 0.13 mm; P = 0.008). Early lumen loss is common after the treatment of in-stent restenosis by balloon angioplasty. Within the first 6 hr postintervention, 32% +/- 29% of acute lumen gain is lost, and early lumen loss contributed to 42% +/- 18% of total lumen loss at follow-up. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 13 条
[1]  
Ahmed JM, 2001, CIRCULATION, V103, P188
[2]   MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE) [J].
BAIM, DS ;
LEVINE, MJ ;
LEON, MB ;
LEVINE, S ;
ELLIS, SG ;
SCHATZ, RA .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) :364-366
[3]  
Bauters C, 1998, CIRCULATION, V97, P318
[4]   Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Pache, J ;
Wehinger, A ;
Hadamitzky, M ;
Dirschinger, J ;
Neumann, FJ ;
Schömig, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1866-1873
[5]  
Malhotra S, 2001, CATHETER CARDIO INTE, V52, P35
[6]   Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis [J].
Mehran, R ;
Mintz, GS ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06) :618-622
[7]   Treatment of focal in-stent restenosis with balloon angioplasty alone versus stenting: Short- and long-term results [J].
Mehran, R ;
Dangas, G ;
Abizaid, A ;
Lansky, AJ ;
Mintz, GS ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Waksman, R ;
Stone, GW ;
Leon, MB .
AMERICAN HEART JOURNAL, 2001, 141 (04) :610-614
[8]   A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. [J].
Morice, M ;
Serruys, PW ;
Sousa, JE ;
Fajadet, J ;
Hayashi, EB ;
Perin, M ;
Colombo, A ;
Schuler, G ;
Barragan, P ;
Guagliumi, G ;
Molnar, F ;
Falotico, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) :1773-1780
[9]   Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery [J].
Moses, JW ;
Leon, MB ;
Popma, JJ ;
Fitzgerald, PJ ;
Holmes, DR ;
O'Shaughnessy, C ;
Caputo, RP ;
Kereiakes, DJ ;
Williams, DO ;
Teirstein, PS ;
Jaeger, JL ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) :1315-1323
[10]   Early lumen loss after treatment of in-stent restenosis - An intravascular ultrasound study [J].
Shiran, A ;
Mintz, GS ;
Waksman, R ;
Mehran, R ;
Abizaid, A ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Popma, JJ ;
Leon, MB .
CIRCULATION, 1998, 98 (03) :200-203