Mechanisms and results of balloon angioplasty for the treatment of in-stent restenosis

被引:143
作者
Mehran, R
Mintz, GS
Popma, JJ
Pichard, AD
Satler, LF
Kent, KM
Griffin, J
Leon, MB
机构
[1] WASHINGTON HOSP CTR,INTRAVASC ULTRASOUND IMAGING LAB,WASHINGTON,DC 20010
[2] WASHINGTON HOSP CTR,CARDIAC CATHETERIZAT LAB,WASHINGTON,DC 20010
关键词
D O I
10.1016/S0002-9149(96)00381-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Restenosis within tubular slotted stents is secondary to intimal hyperplasia and is usually treated with percutaneous transluminal coronary angioplasty (PTCA). Sequential intravascular ultrasound (IVUS) was used to assess the mechanisms and results of PTCA for in-stent restenosis. Sixty-four restenotic Palmaz-Schatz stents were studied by IVUS imaging before and after PTCA. NUS measurements of stent and lumen cross-sectional areas (CSAs) at 5 segments (proximal and distal stent edges, proximal and distal stent bodies, and the central articulation) were used to calculate intimal hyperplasia CSA (stent - lumen CSA). The results of the 5 segments were then averaged. Mean and minimum CSAs were compared before and after PTCA. Quantitative angiographic, measurements showed a minimal lumen diameter increase from 1.05 +/- 0.63 mm (mean +/- 1 SD) before intervention to 2.77 +/- 0.51 mm after PTCA (p <0.0001). Conversely, the diameter stenosis decreased from 63 +/- 19% to 18 +/- 12% (p <0.0001). IVUS measurements showed a minimum lumen CSA increase from 2.3 +/- 1.3 mm(2) to 6.1 +/- 2.2 mm(2) (p <0.0001) as a result of an increased minimum stent CSA (7.2 +/- 2.4 mm(2) to 8.7 +/- 2.6 mm(2), P <0.0001) and a decreased intimal hyperplasia CSA within the stent (4.9 +/- 2.2 mm(2) to 2.7 +/- 2.0 mm(2), p <0.0001). Of the total mean lumen enlargement, 56 +/- 28% was the result of additional stent expansion and 44 +/- 28% was the result of a decrease in neointimal tissue. The minimum lumen CSA after PTCA was significantly smaller than the minimum stent CSA before PTCA (presumably an accurate reflection of lumen dimensions immediately after stent implantation; p = 0.0002). The mechanism of PTCA for restenosis is a combination of additional stent expansion and tissue extrusion out of the stent; there is a relatively high residual stenosis (angiographic diameter stenosis of 18 +/- 12%).
引用
收藏
页码:618 / 622
页数:5
相关论文
共 7 条
  • [1] SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS
    DUSSAILLANT, GR
    MINTZ, GS
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    WONG, SC
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 720 - 724
  • [2] BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS
    GOLDBERG, SL
    COLOMBO, A
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    TOBIS, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 996 - 1003
  • [3] MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT
    GORDON, PC
    GIBSON, CM
    COHEN, DJ
    CARROZZA, JP
    KUNTZ, RE
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1166 - 1174
  • [4] HOFFMANN R, IN PRESS CIRCULATION
  • [5] BALLOON ANGIOPLASTY FOR TREATMENT OF IN-STENT RESTENOSIS - FEASIBILITY, SAFETY, AND EFFICACY
    MACANDER, PJ
    ROUBIN, GS
    AGRAWAL, SK
    CANNON, AD
    DEAN, LS
    BAXLEY, WA
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (02): : 125 - 131
  • [6] Axial plaque redistribution as a mechanism of percutaneous transluminal coronary angioplasty
    Mintz, GS
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Leon, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (05) : 427 - &
  • [7] SERIAL INTRAVASCULAR ULTRASOUND STUDIES FAIL TO SHOW EVIDENCE OF CHRONIC PALMAZ-SCHAH STENT RECOIL
    PAINTER, JA
    MINTZ, GS
    WONG, SC
    POPMA, JJ
    PICHARD, AD
    KENT, KM
    SATLER, LF
    LEON, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (05) : 398 - 400