Hypothetical mortality risk associated with spiral tomography of the maxilla and mandible prior to endosseous implant treatment

被引:20
作者
Dula, K
Mini, R
Lambrecht, JT
vanderStelt, PF
Schneeberger, P
Clemens, G
Sanderink, H
Buser, D
机构
[1] ACAD CTR DENT AMSTERDAM,SCH DENT,DEPT ORAL RADIOL,AMSTERDAM,NETHERLANDS
[2] UNIV BERN,SCH MED,DEPT RADIOONCOL,DIV MED RADIAT PHYS,BERN,SWITZERLAND
[3] UNIV BASEL,SCH DENT,DEPT ORAL SURG ORAL RADIOL & ORAL MED,BASEL,SWITZERLAND
关键词
spiral tomography; scanora; mortality risk; radiation dose;
D O I
10.1111/j.1600-0722.1997.tb00190.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Radiation dose delivered from the SCANORA(R) radiography unit during the cross-sectional mode for dentotangential projections was determined. With regard to oral implantology, patient situations of an edentulous maxilla and mandible as well as a single tooth gap in regions 16 and 46 were simulated. Radiation doses were measured between 0.2 and 22.5 mGy to organs and tissues in the head and neck region when the complete maxilla or mandible was examined. When examining a single tooth gap, only 8% to 40% of that radiation dose was generally observed. Based on these results, the mortality risk was estimated according to a calculation model recommended by the Committee on the Biological Effects of Ionizing Radiations. The mortality risk ranged from 31.4 x 10(-6) for 20-year-old men to 4.8 x 10(-6) for 65-year-old women when cross-sectional imaging of the complete maxilla was performed. The values decreased by 70% when a single tooth gap in the molar region of the maxilla was radiographed. The figures for the mortality risk for examinations of the complete mandible were similar to those for the complete maxilla, but the mortality risk decreased by 80% if only a single tooth gap in the molar region of the mandible was examined. Calculations according to the International Commission on Radiological Protection carried out for comparison did not reveal the decrease of the mortality risk with age and resulted in a higher risk value in comparison to the group of 35-year old individuals in calculations according to the Committee on the Biological Effects of Ionizing Radiations.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 21 条
[1]  
[Anonymous], 1990, ICRP PUBL
[2]  
BOCAGE AEM, 1922, Patent No. 536464
[3]  
CLARK D E, 1990, Journal of Oral Implantology, V16, P156
[4]  
*COMM BIOL EFF ION, 1980, EFFECTS POPULATIONS
[5]  
*COMM BIOL EFF ION, 1991, HLTH EFF EXP LOW LEV
[6]   Hypothetical mortality risk associated with spiral computed tomography of the maxilla and mandible [J].
Dula, K ;
Mini, R ;
vanderStelt, PF ;
Lambrecht, JT ;
Schneeberger, P ;
Buser, D .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1996, 104 (5-6) :503-510
[7]  
Ekestubbe A, 1993, Dentomaxillofac Radiol, V22, P13
[8]  
Ekestubbe A, 1992, Dentomaxillofac Radiol, V21, P65
[9]   RELIABILITY OF SPIRAL TOMOGRAPHY WITH THE SCANORA(R) TECHNIQUE FOR DENTAL IMPLANT PLANNING [J].
EKESTUBBE, A ;
GRONDAHL, HG .
CLINICAL ORAL IMPLANTS RESEARCH, 1993, 4 (04) :195-202
[10]   EFFECTIVE DOSE AND RISK ASSESSMENT FROM FILM TOMOGRAPHY USED FOR DENTAL IMPLANT DIAGNOSTICS [J].
FREDERIKSEN, NL ;
BENSON, BW ;
SOKOLOWSKI, TW .
DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (03) :123-127